background image

OmniSwitch 6850-P24X

OmniSwitch 6850 Series Chassis and Hardware Components

page 2-48

OmniSwitch 6850/6850E Series Hardware Users Guide

June 2011

Connections supported

IP phones, Bluetooth Access Points, Internet cameras, and other 
devices requiring power over Ethernet

Cable supported
(RJ-45)

10BaseT: unshielded twisted-pair (UTP)
100BaseTX: unshielded twisted-pair (UTP), Category 5, EIA/TIA 568 
or shielded twisted-pair (STP), Category 5, 100 ohm
1000BaseT: unshielded twisted-pair (UTP), Category 5e

Power supplied to port

15.4 watts per port

Maximum cable distance
(RJ-45)

100 meters

OS6850-P24X Specifications 

Содержание OS6850-48

Страница 1: ...Part No 060209 10 Rev K June 2011 OmniSwitch 6850 6850E Series Hardware Users Guide www alcatel lucent com...

Страница 2: ...atel Lucent OmniVista are registered trademarks of Alcatel Lucent OmniAccess Omni Switch Router PolicyView RouterView SwitchManager VoiceView WebView X Cell X Vision and the Xylan logo are trademarks...

Страница 3: ...al Support xv Chapter 1 OmniSwitch 6850 6850E Series 1 1 Availability Features 1 2 Software Rollback 1 2 Backup Power Supplies 1 2 Hot Swapping 1 3 Hardware Monitoring 1 3 Chapter 2 OmniSwitch 6850 Se...

Страница 4: ...Power Cords 2 67 Specifications 2 67 Console Port 2 68 Serial Connection Default Settings 2 68 Modifying the Serial Connection Settings 2 68 Console Port Pinouts 2 70 10 100 Ethernet Port RJ 45 Pinout...

Страница 5: ...t Port RJ 45 Pinout 3 34 10 100 1000 Mbps Power over Ethernet Port RJ 45 Pinout 3 34 RJ 45 Console Port Connector Pinout 3 35 Chapter 4 OmniSwitch 6850 6850E Series Power Supplies 4 1 OmniSwitch 6850...

Страница 6: ...ity Disconnect is Enabled Incoming PD Port has Highest Priority Level 5 10 Priority Disconnect is Enabled Incoming PD Port has Lowest Priority Level 5 10 Priority Disconnect is Disabled 5 11 Monitorin...

Страница 7: ...6 40 Appendix A Regulatory Compliance and Safety Information A 1 Declaration of Conformity CE Mark A 1 Waste Electrical and Electronic Equipment WEEE Statement A 1 China RoHS Hazardous Substance Tabl...

Страница 8: ...er a de litio A 12 Advertencia sobre la tensi n de operaci n A 12 Advertencia sobre la desconexi n de la fuente A 12 Advertencia sobre una apropiada conexi n a tierra A 13 Leer informaci n importante...

Страница 9: ...es your switch hardware components and basic switch hardware procedures Supported Platforms This information in this guide applies to the following products OmniSwitch 6850 24 24L P24 P24L 24X P24X Om...

Страница 10: ...une 2011 Unsupported Platforms The information in this guide does not apply to the following products OmniSwitch original version with no numeric model name OmniSwitch 6600 Family OmniSwitch 6800 Seri...

Страница 11: ...es backup power supplies etc in greater depth What is in this Manual This users guide includes the following hardware related information Descriptions of stand alone and stacked configurations Descrip...

Страница 12: ...up a password and setting up stacks It also includes succinct overview information on fundamental aspects of the switch such as hardware LEDs the soft ware directory structure stacking CLI conventions...

Страница 13: ...Configuration Guide contains overview information procedures and examples on how standard networking technologies are configured on the OmniSwitch The OmniSwitch AOS Release 6 Advanced Routing Config...

Страница 14: ...ude the software directory architecture image rollback protections authenticated switch access managing switch files system configuration using SNMP and using web management software WebView OmniSwitc...

Страница 15: ...excuses technical support You ll also receive regular software updates to maintain and maximize your Alcatel Lucent prod uct s features and functionality and on site hardware replacement through our...

Страница 16: ...Technical Support About This Guide page xvi OmniSwitch 6850 6850E Series Hardware Users Guide June 2011...

Страница 17: ...rate layer 2 forwarding and layer 3 routing with advanced services effective availability resiliency and security features and are ideal for the following network applications Enterprise workgroups LA...

Страница 18: ...o referred to as image rollback essentially allows the OmniSwitch to return to a prior last known good version of software in the event of a system software problem The switch controls software rollba...

Страница 19: ...ds a trap to the user The trap is displayed on the console in the form of a text error message In the case of an over threshold temperature condition the chassis displays an amber TMP LED in addition...

Страница 20: ...Availability Features OmniSwitch 6850 6850E Series page 1 4 OmniSwitch 6850 6850E Series Hardware Users Guide June 2011...

Страница 21: ...0 P48L 48 port 10 100 Power over Ethernet PoE OmniSwitch 6850 U24X OS6850 U24X 24 port Gigabit SFP with 10 Gigabit uplinks OmniSwitch 6850 24 OS6850 24 24 port 10 100 1000 OmniSwitch 6850 48 OS6850 48...

Страница 22: ...11 This chapter includes detailed information on these chassis types Topics include OmniSwitch 6850 Series chassis descriptions Technical specifications Switch mounting Booting OmniSwitch 6850 Series...

Страница 23: ...figurable to be 10 100 1000Base T or 1000Base X high speed connections The front panel of the OS6850 24L chassis contains the following major components System status and slot indicator LEDs 20 unshar...

Страница 24: ...nector provides a DTE console connection Status and Slot Indicator LEDs For information on the OS6850 24L s status and slot indicator LEDs refer to page 2 53 USB Port High speed USB port which can be...

Страница 25: ...10 5 inches without power supplies installed 16 75 inches with power supplies installed Weight 14 lbs 6 24 Kg approx Humidity 5 to 90 Relative Humidity Operating 0 to 95 Relative Humidity Storage Ope...

Страница 26: ...witch 6850 24L OmniSwitch 6850 Series Chassis and Hardware Components page 2 6 OmniSwitch 6850 6850E Series Hardware Users Guide June 2011 Maximum cable distance RJ 45 100 meters OS6850 24L Specificat...

Страница 27: ...nfigurable to 10 100 1000Base T or 1000Base X high speed connec tions The front panel of the OS6850 48L chassis contains the following major components System status and slot indicator LEDs 44 unshare...

Страница 28: ...atus and Slot Indicator LEDs For detailed information on OS6850 48L status and slot indicator LEDs refer to page 2 53 USB Port High speed USB port which can be used for quick upgrades Combo SFP The OS...

Страница 29: ...pplies installed 16 75 inches with power supplies installed Weight 14 lbs 6 24 Kg approx Humidity 5 to 90 Relative Humidity Operating 0 to 95 Relative Humidity Storage Operating Temperature 0 to 45 de...

Страница 30: ...configurable to be 10 100 1000Base T PoE or 1000Base X high speed connections The front panel of the OS6850 P24L chassis contains the following major components System status and slot indicator LEDs 2...

Страница 31: ...J 45 con nector provides a DTE console connection Status and Slot Indicator LEDs For information on the OS6850 P24L s status and slot indicator LEDs refer to page 2 53 USB Port High speed port which c...

Страница 32: ...s Height 1 73 inches Height rack units 1 RU Chassis Depth 10 5 inches without power supplies installed 16 75 inches with power supplies installed Weight 14 lbs 6 24 Kg approx Humidity 5 to 90 Relative...

Страница 33: ...page 2 13 Cable supported RJ 45 10BaseT unshielded twisted pair UTP 100BaseTX unshielded twisted pair UTP Category 5 EIA TIA 568 or shielded twisted pair STP Category 5 100 ohm 1000BaseT unshielded tw...

Страница 34: ...y configurable to 10 100 1000Base T PoE or 1000Base X high speed connections The front panel of the OS6850 P48L chassis contains the following major components System status and slot indicator LEDs 44...

Страница 35: ...nection Status and Slot Indicator LEDs For detailed information on OS6850 P48L s status and slot indica tor LEDs refer to page 2 53 USB Port High speed USB port which can be used for quick upgrades Co...

Страница 36: ...Height 1 73 inches Height rack units 1 RU Chassis Depth 10 5 inches without power supplies installed 16 75 inches with power supplies installed Weight 14 lbs 6 24 Kg approx Humidity 5 to 90 Relative...

Страница 37: ...page 2 17 Cable supported RJ 45 10BaseT unshielded twisted pair UTP 100BaseTX unshielded twisted pair UTP Category 5 EIA TIA 568 or shielded twisted pair STP Category 5 100 ohm 1000BaseT unshielded tw...

Страница 38: ...ering 24 1000Base X SFP connectors two 2 10 Gigabit XFP connectors as well as four combo individually configurable to 10 100 1000Base T The front panel of the OS6850 U24X chassis contains the followin...

Страница 39: ...provides two combo 10 100 1000BaseT By default when an SFP is installed in a combo port it takes over the port number of the corresponding RJ 45 Ethernet port In other words if an SFP is installed in...

Страница 40: ...ssis Width rack mount flanges not included 17 5 inches Height 1 73 inches Height rack units 1 RU Chassis Depth 10 5 inches without power supplies installed 16 75 inches with power supplies installed W...

Страница 41: ...sers Guide June 2011 page 2 21 Cable supported RJ 45 10BaseT unshielded twisted pair UTP 100BaseTX unshielded twisted pair UTP Category 5 EIA TIA 568 or shielded twisted pair STP Category 5 100 ohm 10...

Страница 42: ...witch offering 20 unshared 10 100 1000 Base T as well as four combo individually configurable to be 10 100 1000 Base T or 1000 Base X high speed connections The front panel of the OS6850 24 chassis co...

Страница 43: ...RJ 45 port for console connections Console connec tions are used by network admin istrators for switch management This female RJ 45 connector provides a DTE console connec tion Status and Slot Indica...

Страница 44: ...epth 10 5 inches without power supplies installed 16 75 inches with power supplies installed Weight 14 lbs 6 24 Kg approx Humidity 5 to 90 Relative Humidity Operating 0 to 95 Relative Humidity Storage...

Страница 45: ...Switch 6850 Series Chassis and Hardware Components OmniSwitch 6850 24 OmniSwitch 6850 6850E Series Hardware Users Guide June 2011 page 2 25 Maximum cable distance RJ 45 100 meters OS6850 24 Specificat...

Страница 46: ...p switch offering 44 unshared 10 100 1000Base T as well as four combo individually configurable to 10 100 1000Base T or 1000Base X high speed connec tions The front panel of the OS6850 48 chassis cont...

Страница 47: ...us and Slot Indicator LEDs For detailed information on OS6850 48 status and slot indicator LEDs refer to page 2 53 OmniSwitch 6850 48 USB Console OK PRI PWR BPS CLASS 1 LASER PRODUCT 1 2 3 4 1 2 3 4 5...

Страница 48: ...5 inches without power supplies installed 16 75 inches with power supplies installed Weight 14 lbs 6 24 Kg approx Humidity 5 to 90 Relative Humidity Operating 0 to 95 Relative Humidity Storage Operat...

Страница 49: ...Switch 6850 Series Chassis and Hardware Components OmniSwitch 6850 48 OmniSwitch 6850 6850E Series Hardware Users Guide June 2011 page 2 29 Maximum cable distance RJ 45 100 meters OS6850 48 Specificat...

Страница 50: ...1000 Base T Power over two 2 10 Gigabit XFP connectors as well as four combo individually configurable to 10 100 1000 Base T or 1000 Base X high speed connections The front panel of the OS6850 24X ch...

Страница 51: ...s four combo SFP connectors for 1000Base X high speed connections By default when an SFP is installed in a combo port it takes over the port number of the corresponding RJ 45 Ethernet port In other wo...

Страница 52: ...idth rack mount flanges not included 17 5 inches Height 1 73 inches Height rack units 1 RU Chassis Depth 10 5 inches without power supplies installed 16 75 inches with power supplies installed Weight...

Страница 53: ...sers Guide June 2011 page 2 33 Cable supported RJ 45 10BaseT unshielded twisted pair UTP 100BaseTX unshielded twisted pair UTP Category 5 EIA TIA 568 or shielded twisted pair STP Category 5 100 ohm 10...

Страница 54: ...ch 6850 48X The OmniSwitch 6850 48X is a stackable edge workgroup switch offering 48 unshared 10 100 1000Base T and two 2 10 Gigabit XFP connectors The front panel of the OS6850 48X chassis contains t...

Страница 55: ...t The front panel provides one RJ 45 port for console connections Console connections are used by network administrators for switch management This female RJ 45 connector provides a DTE console connec...

Страница 56: ...dity 5 to 90 Relative Humidity Operating 0 to 95 Relative Humidity Storage Operating Temperature 0 to 45 degrees Celsius Storage Temperature 20 to 70 degrees Celsius Altitude Operating altitude sea le...

Страница 57: ...20 unshared 10 100 1000 Base T Power over Ethernet PoE as well as four combo individually configurable to 10 100 1000 Base T PoE or 1000 Base X high speed connections The front panel of the OS6850 P24...

Страница 58: ...n nector provides a DTE console connection Status and Slot Indicator LEDs For information on the OS6850 P24 s status and slot indicator LEDs refer to page 2 53 USB Port High speed USB port which can b...

Страница 59: ...nches Height 1 73 inches Height rack units 1 RU Chassis Depth 10 5 inches without power supplies installed 16 75 inches with power supplies installed Weight 14 lbs 6 24 Kg approx Humidity 5 to 90 Rela...

Страница 60: ...June 2011 Cable supported RJ 45 10BaseT unshielded twisted pair UTP 100BaseTX unshielded twisted pair UTP Category 5 EIA TIA 568 or shielded twisted pair STP Category 5 100 ohm 1000BaseT unshielded tw...

Страница 61: ...44 unshared 10 100 1000 Base T Power over Ethernet PoE as well as four combo individually configurable to 10 100 1000 Base T PoE or 1000 Base X high speed connections The front panel of the OS6850 P48...

Страница 62: ...onnection Status and Slot Indicator LEDs For information on the OS6850 P48 s status and slot indicator LEDs refer to page 2 53 USB Port High speed USB port which can be used for quick upgrades OmniSwi...

Страница 63: ...inches Height 1 73 inches Height rack units 1 RU Chassis Depth 10 5 inches without power supplies installed 16 75 inches with power supplies installed Weight 14 lbs 6 24 Kg approx Humidity 5 to 90 Rel...

Страница 64: ...June 2011 Cable supported RJ 45 10BaseT unshielded twisted pair UTP 100BaseTX unshielded twisted pair UTP Category 5 EIA TIA 568 or shielded twisted pair STP Category 5 100 ohm 1000BaseT unshielded tw...

Страница 65: ...Power over Ethernet PoE two 2 10 Gigabit XFP connectors as well as four combo individu ally configurable to 10 100 1000 Base T PoE or 1000 Base X high speed connections The front panel of the OS6850...

Страница 66: ...es two for 10 Gbps Small Form Factor Pluggable XFP transceiv ers OmniSwitch 6850 P24X USB Console OK PRI PWR BPS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 26 25 CLASS 1 LASE...

Страница 67: ...hassis Width rack mount flanges not included 17 5 inches Height 1 73 inches Height rack units 1 RU Chassis Depth 10 5 inches without power supplies installed 16 75 inches with power supplies installed...

Страница 68: ...ints Internet cameras and other devices requiring power over Ethernet Cable supported RJ 45 10BaseT unshielded twisted pair UTP 100BaseTX unshielded twisted pair UTP Category 5 EIA TIA 568 or shielded...

Страница 69: ...e OmniSwitch 6850 P48X is a stackable edge workgroup switch offering 48 unshared 10 100 1000Base T Power over Ethernet PoE and two 2 10 Gigabit XFP connectors The front panel of the OS6850 P48X chassi...

Страница 70: ...2 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 10 100 1000Mbps PoE The OS6850 P48X provides 48 fixed 10 100 1000BaseT non combo PoE 1 48 These are auto sensing and auto MDIX and use RJ 45 connector...

Страница 71: ...Relative Humidity Storage Operating Temperature 0 to 45 degrees Celsius Storage Temperature 20 to 70 degrees Celsius Altitude Operating altitude sea level at 40 degrees Celsius and 10000 feet at 0 deg...

Страница 72: ...h 6850 P48X OmniSwitch 6850 Series Chassis and Hardware Components page 2 52 OmniSwitch 6850 6850E Series Hardware Users Guide June 2011 Maximum cable distance RJ 45 RJ 45 100 meters OS6850 P48X Speci...

Страница 73: ...7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 Slot Indicator LED The slot indicator LED dis plays the switch s current slot...

Страница 74: ...plays blinking green when transmitting or receiving packets in a link up state off when no link is detected It displays solid amber 10 100 Mbps for a valid link displays blinking amber when transmit t...

Страница 75: ...n optional redundant power supply Two stacking A and B Grounding block for type LCD8 10A L grounding lug Note The figure shows a pre production version of the chassis without product safety and compli...

Страница 76: ...ord s OmniSwitch 6850 Series Chassis Top View Note Never obstruct the air vents located at the sides of the chassis Obstructing these vents can cause switch failure Clearance is not required at the to...

Страница 77: ...es Otherwise airflow may become restricted Restricted airflow can cause your switch to overheat overheating can lead to switch failure See Airflow Considerations on page 2 56 for more information on c...

Страница 78: ...ive internal switch components from physical damage by closing off the chassis When blank cover panels are missing air does not take the direct route from the air intake vent through the chassis and t...

Страница 79: ...sides of the switch For recommended clearances refer to page 2 56 Also be sure that you have placed the chassis within the reach of all the required AC power sources 3 If you are installing a single i...

Страница 80: ...rack mounting hardware For more information contact your Alcatel Lucent representative Alcatel Lucent does not provide rack mount screws Use the screws supplied by the rack vendor To prevent a rack f...

Страница 81: ...are secure Attaching the Switch to the Rack Note Be sure to install the screws in the bottom hole of each flange as shown before proceeding 7 Once the screws at the bottom of each flange are secure in...

Страница 82: ...most switch and bottom most switch in the stack must be connected using a redundant stacking cable Refer to Chapter 6 Managing OmniSwitch 6850 6850E Series Stacks for more information on the redundan...

Страница 83: ...iled information on cabling patterns Be sure that cable connector is completely inserted and fully seated in the chassis 3 Insert the other end of the stacking cable into the stacking port of the swit...

Страница 84: ...to the bottom switch Connect the redundant cable now Refer to the diagram below for more information Redundant Connection Between Top and Bottom Switches 6 Once all stacking cable connectors are inser...

Страница 85: ...ers from the states shown in the table above refer to page 2 53 for more infor mation Contact Alcatel Lucent Customer Support if the LED state persists For information on logging in and configuring yo...

Страница 86: ...for more infor mation Contact Alcatel Lucent Customer Support if the LED state persists For information on logging in and configuring your OmniSwitch 6850 Series stack refer to the OmniSwitch 6850 Ser...

Страница 87: ...es in an IEC 320 attachment plug and the other end terminates in a NEMA 5 15P plug The power cord to be used with 230 Volt configuration is minimum type SJT SVT 18 3 rated 250 Volts AC 10 Amps with a...

Страница 88: ...ge will display For switches in a stacked configuration all changes must be configured before the switches are cabled together In other words you must configure these settings when each switch is oper...

Страница 89: ...ile at the boot prompt Boot commit file When the commit file command is used changes will not be enabled until after the next switch reboot 8 You can also save your changes in real time to the switch...

Страница 90: ...Ethernet Port RJ 45 Pinout non PoE Gigabit Ethernet Port RJ 45 Pinout 10 100 1000 Mbps Power over Ethernet Port RJ 45 Pinout Pin Number Description 1 RX 2 RX 3 TX 4 not used 5 not used 6 TX 7 not used...

Страница 91: ...and Hardware Components Console Port OmniSwitch 6850 6850E Series Hardware Users Guide June 2011 page 2 71 RJ 45 Console Port Connector Pinout Pin Number Signals as DTE Console Port 1 NC 2 NC 3 RXD 4...

Страница 92: ...Console Port OmniSwitch 6850 Series Chassis and Hardware Components page 2 72 OmniSwitch 6850 6850E Series Hardware Users Guide June 2011...

Страница 93: ...mniSwitch 6850E P24 on page 3 5 OmniSwitch 6850E 24X see OmniSwitch 6850E 24X on page 3 8 OmniSwitch 6850E P24X see OmniSwitch 6850E P24X on page 3 11 OmniSwitch 6850E 48 see OmniSwitch 6850E 48 on pa...

Страница 94: ...rt C System Status LEDs Provides status on hardware software primary and redundant power D 10 100 1000BaseT RJ 45 Ports and LEDs 10 100 1000BaseT non combo and 10 100 1000BaseT combo ports Odd numbere...

Страница 95: ...el Item Description A Grounding Block Type LCD8 10A L grounding lug B Redundant Power Supply Connector DB 25 connector for optional external redundant power supply C Primary Power Supply Connector DB...

Страница 96: ...50E Series Power Supplies on page 4 2 Flash memory size 128 MB RAM memory size 512 MB SDRAM Width 17 32 in 44 0 cm Height 1 73 in 4 4 cm Height rack units 1 RU Depth 10 59 in 26 9 cm Weight 8 36 lbs 3...

Страница 97: ...us on hardware software primary and redundant power D 10 100 1000BaseT RJ 45 PoE Ports and LEDs 10 100 1000BaseT non combo and 10 100 1000BaseT combo ports Odd numbered ports are on top row even numbe...

Страница 98: ...ary power supply must be connected to the primary connector A redundant power supply can be connected to either of the redundant connectors Item Description A Redundant Power Supply Connector DB 25 co...

Страница 99: ...tack 16 Power See OmniSwitch 6850 6850E Series Power Supplies on page 4 2 Flash memory size 128 MB RAM memory size 512 MB SDRAM Width 17 32 in 44 0 cm Height 1 73 in 4 4 cm Height rack units 1 RU Dept...

Страница 100: ...0 100 1000BaseT RJ 45 Ports and LEDs 10 100 1000BaseT non combo and 10 100 1000BaseT combo ports Odd numbered ports are on top row even numbered ports are on bottom row E SFP Combo Ports and LEDs Comb...

Страница 101: ...nel Item Description A Grounding Block Type LCD8 10A L grounding lug B Redundant Power Supply Connector DB 25 connector for optional external redundant power supply C Primary Power Supply Connector DB...

Страница 102: ...50E Series Power Supplies on page 4 2 Flash memory size 128 MB RAM memory size 512 MB SDRAM Width 17 32 in 44 0 cm Height 1 73 in 4 4 cm Height rack units 1 RU Depth 10 59 in 26 9 cm Weight 8 40 lbs 3...

Страница 103: ...100 1000BaseT RJ 45 PoE Ports and LEDs 10 100 1000BaseT non combo and 10 100 1000BaseT combo ports Odd numbered ports are on top row even numbered ports are on bottom row E SFP Combo Ports and LEDs C...

Страница 104: ...r supply must be connected to the primary connector A redundant power supply can be connected to either of the redundant connectors Item Description A Redundant Power Supply Connector DB 25 connector...

Страница 105: ...stack 16 Power See OmniSwitch 6850 6850E Series Power Supplies on page 4 2 Flash memory size 128 MB RAM memory size 512 MB SDRAM Width 17 32 in 44 0 cm Height 1 73 in 4 4 cm Height rack units 1 RU Dep...

Страница 106: ...rt C System Status LEDs Provides status on hardware software primary and redundant power D 10 100 1000BaseT RJ 45 Ports and LEDs 10 100 1000BaseT non combo and 10 100 1000BaseT combo ports Odd numbere...

Страница 107: ...ation labels All production versions of the chassis have these labels OS6850E 48 Rear Panel Item Description A Grounding Block Type LCD8 10A L grounding lug B Redundant Power Supply Connector DB 25 co...

Страница 108: ...6850 6850E Series Power Supplies on page 4 2 Flash memory size 128 MB RAM memory size 512 MB SDRAM Width 17 32 in 44 0 cm Height 1 73 in 4 4 cm Height rack units 1 RU Depth 10 59 in 26 9 cm Weight 8...

Страница 109: ...t C System Status LEDs Provides status on hardware software primary and redundant power D 10 100 1000BaseT RJ 45 PoE Ports and LEDs 10 100 1000BaseT non combo and 10 100 1000BaseT combo ports Odd numb...

Страница 110: ...supply must be connected to the primary connector A redundant power supply can be connected to either of the redundant connectors Item Description A Redundant Power Supply Connector DB 25 connector f...

Страница 111: ...Per stack 16 Power See OmniSwitch 6850 6850E Series Power Supplies on page 4 2 Flash memory size 128 MB RAM memory size 512 MB SDRAM Width 17 32 in 44 0 cm Height 1 73 in 4 4 cm Height rack units 1 R...

Страница 112: ...dware software primary and redundant power D 10 100 1000BaseT RJ 45 Ports and LEDs 10 100 1000BaseT non combo and 10 100 1000BaseT combo ports Odd numbered ports are on top row even numbered ports are...

Страница 113: ...anel Item Description A Grounding Block Type LCD8 10A L grounding lug B Redundant Power Supply Connector DB 25 connector for optional external redundant power supply C Primary Power Supply Connector D...

Страница 114: ...6850 6850E Series Power Supplies on page 4 2 Flash memory size 128 MB RAM memory size 512 MB SDRAM Width 17 32 in 44 0 cm Height 1 73 in 4 4 cm Height rack units 1 RU Depth 10 59 in 26 9 cm Weight 8...

Страница 115: ...are software primary and redundant power D 10 100 1000BaseT RJ 45 PoE Ports and LEDs 10 100 1000BaseT non combo and 10 100 1000BaseT combo ports Odd numbered ports are on top row even numbered ports a...

Страница 116: ...r supply must be connected to the primary connector A redundant power supply can be connected to either of the redundant connectors Item Description A Redundant Power Supply Connector DB 25 connector...

Страница 117: ...Per stack 16 Power See OmniSwitch 6850 6850E Series Power Supplies on page 4 2 Flash memory size 128 MB RAM memory size 512 MB SDRAM Width 17 32 in 44 0 cm Height 1 73 in 4 4 cm Height rack units 1 R...

Страница 118: ...lement ID B USB Port High speed USB port C System Status LEDs Provides status on hardware software primary and redundant power D SFP Ports and LEDs Combo and non combo SFP connectors for various suppo...

Страница 119: ...Panel Item Description A Grounding Block Type LCD8 10A L grounding lug B Redundant Power Supply Connector DB 25 connector for optional external redundant power supply C Primary Power Supply Connector...

Страница 120: ...sh memory size 128 MB RAM memory size 512 MB SDRAM Width 17 32 in 44 0 cm Height 1 73 in 4 4 cm Height rack units 1 RU Depth 10 59 in 26 9 cm Weight 8 31 lbs 3 77 kg Relative Humidity Operating 5 to 9...

Страница 121: ...ule Refer to OmniSwitch 6850E LED Status Indicators on page 3 31 for LED status information Refer to OmniSwitch 6850E Port Numbering on page 3 30 for port numbering To check the status of the uplink s...

Страница 122: ...Switch 6850E Series switches OS6850E Port Numbering Table Non Combo Ports Combo Ports Non Combo SFP Ports Stacking Uplink Ports OS6850E 24 1 20 21 24 25 26 OS6850E P24 1 20 21 24 25 26 OS6850E 24X 1 2...

Страница 123: ...tack Switch is idle not primary or secondary PWR Solid Green Solid Amber Off Primary power supply operational Primary power supply failure Primary power supply not present BPS Solid Green Solid Amber...

Страница 124: ...message will display For switches in a stacked configuration all changes must be configured before the switches are cabled together In other words you must configure these settings when each switch is...

Страница 125: ...file at the boot prompt Boot commit file When the commit file command is used changes will not be enabled until after the next switch reboot 8 You can also save your changes in real time to the switc...

Страница 126: ...inout non PoE Gigabit Ethernet Port RJ 45 Pinout 10 100 1000 Mbps Power over Ethernet Port RJ 45 Pinout Pin Number Description 1 RX 2 RX 3 TX 4 not used 5 not used 6 TX 7 not used 8 not used Pin Numbe...

Страница 127: ...and Hardware Components Console Port OmniSwitch 6850 6850E Series Hardware Users Guide June 2011 page 3 35 RJ 45 Console Port Connector Pinout Pin Number Signals as DTE Console Port 1 NC 2 NC 3 RXD 4...

Страница 128: ...Console Port OmniSwitch 6850E Series Chassis and Hardware Components page 3 36 OmniSwitch 6850 6850E Series Hardware Users Guide June 2011...

Страница 129: ...Supplies OmniSwitch 6850 6850E Series switches various Power over Ethernet PoE and non PoE AC and DC Power supplies This chapter includes detailed information on these power supply types Topics includ...

Страница 130: ...here is a power shelf provided with the unit that slides into the rear of the chassis and is used to hold the power supplies See the table below for valid configurations The power supplies can also be...

Страница 131: ...2011 page 4 3 Power Supply Shelf Alcatel Lucent requires the use of power supply shelf when the power supply is used in a 1U i e 1 5 inches 3 8 cm configuration In a 2U i e 3 inches 7 6 cm configurat...

Страница 132: ...lled as either a primary or redundant power supply 900W AC System PoE Power Supply P S Component Description Model PS 900AC P Provides Primary and Redundant System and PoE For OmniSwitch 6850 6850E 48...

Страница 133: ...either a primary or redundant power supply 510W AC System PoE Power Supply P S Component Description Model PS 510W AC Provides Primary and Redundant System and PoE For OmniSwitch 6850 6850E PoE Models...

Страница 134: ...either a primary or redundant power supply 510W AC Enhanced System PoE Power Supply P S Component Description Model PS 510W AC E Provides Primary and Redundant System and PoE For OmniSwitch 6850 6850...

Страница 135: ...her a primary or redundant power supply 360W AC System PoE Power Supply P S Component Description Model PS 360W AC Provides Primary and Redundant System and PoE For OmniSwitch 6850 6850E PoE Models In...

Страница 136: ...ther a primary or redundant power supply 360W Enhanced AC System PoE Power Supply P S Component Description Model PS 360W AC E Provides Primary and Redundant System and PoE For OmniSwitch 6850 6850E P...

Страница 137: ...wer Supply provides system power and can be installed as a redundant system power supply 126W AC System Power Supply P S Component Description Model PS 126W AC Provides Primary and Redundant System an...

Страница 138: ...provides full system power and can be installed as a redundant system power supply 120W 48VDC System Power Supply P S Component Description Model PS 120W DC Provides Primary and Redundant System and...

Страница 139: ...onal installation steps See DC Power Supply Considerations on page 4 16 for more information Anti Static Warning Before handling any components free yourself of static by wearing a grounding strap or...

Страница 140: ...t a power supply shelf and connect the power supply with a cable Power Supply Shelf Rack Mounting Steps Follow the steps below to rack mount the power supply shelf 1 Align the threaded holes in the pr...

Страница 141: ...y shelf 4 After the rack mount flanges and the power supply are secured to the shelf mark the holes on the rack where the shelf is to be installed 5 Lift and position the shelf until the rack mount fl...

Страница 142: ...with a cable 1 Be sure the switch and power shelf are securely fastened to the rack 2 Connect the proper end of the supplied power supply cable to the appropriately labeled primary or backup connector...

Страница 143: ...wer Supplies OmniSwitch 6850 6850E Series Power Supplies OmniSwitch 6850 6850E Series Hardware Users Guide June 2011 page 4 15 Redundant Small Power Supplies i e 126W Redundant Large Power Supplies i...

Страница 144: ...page 4 12 DC power supplies e g the PS 120W DC have the following additional considerations Connect to a 48V or 60V reliably grounded DC SELV source Use common DC return connections for the DC power...

Страница 145: ...are Users Guide June 2011 page 4 17 Connecting a DC Power Source The DC power supply on your switch contains a power connector with three 3 square slots for connect ing the positive negative and groun...

Страница 146: ...5 mm off the end of each wire removing the outer insulation to expose the copper core 2 Open the clamp for the ground wire slot by inserting a small flat tip screwdriver into the top of the appropria...

Страница 147: ...ctor You should be able to pull on the wire and not dislodge it Warning For DC input voltages the positive wire of the sourcing equipment such as a battery or rectifier must be connected to the positi...

Страница 148: ...user In addition the power LED on the chassis front panel display solid amber Note For detailed LED information refer to Status LEDs on page 2 54 To check the number of power supplies currently opera...

Страница 149: ...ra tional status use the show chassis command For example show chassis Chassis 1 Model Name OS6850 48 Description 10 100 1000 Part Number 902274 10 Hardware Revision 005 Serial Number 439L0024 Manufac...

Страница 150: ...nal Monitoring Commands CLI Commands Used for Monitoring a Chassis show cmm Displays the basic hardware and status information for primary and secondary management modules if applicable show ni Displa...

Страница 151: ...e powering of attached devices via Ethernet For consistency this chapter and the CLI Command Reference Guide refer to the feature as Power over Ethernet PoE Additional terms such as Powered Device PD...

Страница 152: ...CLI Reference Guide Topics and configuration procedures described in this chapter include Power over Ethernet Specifications on page 5 3 Viewing Power Status on page 5 4 Configuring Power over Ethern...

Страница 153: ...oE administrative status Enabled Default PoE operational status Disabled PoE must be activated on a switch by switch basis via the lanpower start com mand Platforms supporting PoE OmniSwitch 6850 PoE...

Страница 154: ...s of power supplies installed in the backup power supply use the show power command as shown below show power Slot PS Wattage Type Status Location 1 1 1 2 360 AC UP External 1 3 2 1 510 AC UP External...

Страница 155: ...ustment based on the power class detected This will prevent the switch from delivering more than the maximum power allowed based on a device s class During class detection the switch will allocate the...

Страница 156: ...e lanpower stop command To disable PoE on a specific PoE capable port enter a slot port number For example lanpower stop 8 22 To disable PoE for all PoE capable in a slot enter the corresponding slot...

Страница 157: ...f power the slot can use to power all attached devices until the value is modified by the user Note Changing the maximum power available to a slot or port does not reserve or immediately allocate that...

Страница 158: ...npower capacitor detection followed by the slot number of the switch and enable For example to enable the capacitor detection method on the switch with slot number 2 enter lanpower capacitor detection...

Страница 159: ...y disconnect uses port priority and port number criteria for determining the power status of incom ing PDs refer to the illustrated examples on pages 5 10 through 5 11 Reminder Priority disconnect app...

Страница 160: ...r off the system software first selects the port with the lowest configured priority level For exam ple if a critical priority device is being added to a slot in which five existing devices are attach...

Страница 161: ...1 Priority Disconnect is Disabled Reminder Priority disconnect examples are applicable only when there is inadequate power remaining to power an incoming device When priority disconnect is disabled po...

Страница 162: ...unt of power budget remaining for PoE modules Total amount of power remaining for additional switch functions When entering the show lanpower command you must include a valid slot number in the comman...

Страница 163: ...to their working as individual stand alone switches an OmniSwitch can also be linked together to work as a single virtual chassis known as a stack With stacks users can easily expand their switching c...

Страница 164: ...s within the stack on page 6 5 Stack cabling on page 6 18 Slot numbering on page 6 22 Hot Swapping modules in a stack on page 6 27 Reloading switches on page 6 29 Changing the secondary module to prim...

Страница 165: ...t 1 saved mode OS6850E Changing OS6850E Daughter Module Mode The OmniSwitch daughter module can be set to either stacking or uplink mode The mode must be set according to the module installed and how...

Страница 166: ...h 6850 6850E Series Hardware Users Guide June 2011 The following example shows how to change the mode to stacking using the interfaces mode command interfaces 1 25 mode stacking WED JUL 01 18 08 29 HS...

Страница 167: ...Module CMM and management module refer to those switches operating in a stack either in the primary or secondary management roles Switches operating in an idle role are essentially acting as network i...

Страница 168: ...A stack of four switches is operating normally The stack consists of a primary module secondary module and two elements operating in idle status The software on all elements in the stack is synchroni...

Страница 169: ...stack consists of a primary module and a secondary module The software on both elements in the stack is synchronized The primary management module fails or is taken offline e g powered off or reboote...

Страница 170: ...econfigured slot information has been cleared For more information on using the lowest MAC address to determine the primary switch in a stack refer to the diagram below Primary Management Module Selec...

Страница 171: ...t is important that each element in a stack is assigned a unique slot number Do not assign duplicate slot numbers to elements in a stack Otherwise one or more switches will be forced into pass through...

Страница 172: ...via stacking cables All switches are currently powered off The user powers on a single switch in the stack In this case the bottom most switch is powered on The user now powers on the remaining switch...

Страница 173: ...ine the secondary management module refer to the diagram below Secondary Management Module Selection Using the Stacking Connection to the Primary Switch Note For information on dynamic slot numbering...

Страница 174: ...pass through mode refer to page 6 14 Primary Slot 1 Slot 3 Slot 4 Secondary Slot 2 Assumes Slot 1 Assumes Slot 3 Assumes Slot 4 Assumes Slot 2 Saved Slot 1 Four switches are stacked all switches are c...

Страница 175: ...ernet ports The primary management module is like an NI module with the added task of overall stack management the secondary management module is like an NI with the added responsibility of backing up...

Страница 176: ...the rest of the stack will not be disrupted Any elements in the stack not operating in pass through mode continue to operate normally The most common reason for one or more switches to enter pass thro...

Страница 177: ...B NI Role State Saved Link A Remote Remote Link B Remote Remote Slot State NI Port State NI Port 1 PRIMARY RUNNING 1 UP 1001 StackA UP 2 StackA 2 SECONDARY RUNNING 2 UP 1 StackB UP 1001 StackB 1001 PA...

Страница 178: ...e and using the optional reload syntax in the command line reboot the module stack set slot 1001 saved slot 3 reload When the module comes up it assumes the new unique slot position in this case slot...

Страница 179: ...StackA 1003 PASS THRU DUP SLOT 2 UP 1002 StackB UP 2 StackA 1002 PASS THRU DUP SLOT 2 UP 1 StackB UP 1003 StackA 1 PRIMARY RUNNING 1 UP 3 StackB UP 1002 StackA 3 IDLE RUNNING 3 UP 4 StackB UP 1 StackA...

Страница 180: ...nded that the cabling pattern remains consistent across the stack In addi tion for a stack to have effective redundancy a redundant stacking cable must be installed between the upper most and bottom m...

Страница 181: ...portant For a stacked configuration to have effective redundancy a redundant stacking cable must be installed between the upper most and bottom most switch in the chassis at all times A stack of eight...

Страница 182: ...lowing a Stacking Link Failure Data enters slot 1 via a 10 100 1000 Ethernet port The data is passed to slot 2 over the stacking cable connection then exits slot 2 via one of its 10 100 1000 Ethernet...

Страница 183: ...acking cable connection exists between the top most and bottom most switches in the stack use the show stack status command For example show stack status Redundant cable status present Tokens used 12...

Страница 184: ...a unique slot number To view the current slot assignments for a stack use the show ni or show module commands The slot number is also displayed on the front panel of each switch by the LED located on...

Страница 185: ...to the diagrams below for more information on dynamic slot numbering Note As the slot numbers are dynamically assigned boot slot cfg files are auto generated in the flash directory of each switch Whe...

Страница 186: ...Numbering Example 2 Slot 5 Idle Slot 4 Idle Slot 3 Idle In this example the bottom switch is elected the primary management module for the stack It can be assumed that this switch has the low est MAC...

Страница 187: ...y and secondary switches at either the top or the bottom of the stack For this example the primary and second ary roles will be assigned to the top of the stack This is accomplished by entering the fo...

Страница 188: ...ack s flash directories use the stack clear slot command on all modules and then reboot the stack For example stack clear slot 1 stack clear slot 2 stack clear slot 3 stack clear slot 4 stack clear sl...

Страница 189: ...econdary management module Also removing a switch from a stacked configuration can disrupt stack cabling at the rear of the stack When removing a module be sure that stacking link integrity including...

Страница 190: ...tack s by following the steps below 1 Make sure all switches are running the same software version 2 Clear the saved slot information from all incoming modules This will ensure that they are each assi...

Страница 191: ...ed For example reload primary Note A primary management module reload can also be scheduled for a later time or date For informa tion on scheduling a primary module reload as well as additional comman...

Страница 192: ...ment module The slot 2 switch is the secondary The user reloads the stack s primary management module by issuing the reload primary command Any data flow on the primary switch s Ethernet is interrupte...

Страница 193: ...ion on scheduling a secondary module reload as well as additional command details refer to the OmniSwitch CLI Reference Guide Reloading the Secondary Management Module In a Stack of Three or More In t...

Страница 194: ...ment module The slot 2 switch is the secondary The user reloads the stack s secondary management module by issuing the reload secondary command Any data flow on the secondary switch s Ethernet is inte...

Страница 195: ...1 is reloaded it resumes its previous idle role Although it has the lowest possible saved slot number it does not take over the primary management role In order for this switch to take over the primar...

Страница 196: ...mary switch s last known good software is propagated to all switches the synchronization process helps ensure effective redundancy across the stack Effects of Saved Slot Number Information on the Relo...

Страница 197: ...tches that do not have saved slot information The primary management role will be given to the switch with the lowest saved slot number The secondary management role will be given to the switch with t...

Страница 198: ...top switch in the stack and the third from top switch in the stack are reloaded simultaneously a problem will occur The switch between the two non adjacent switches will become isolated and the virtu...

Страница 199: ...the switches in the stack are synchronized Otherwise data flow and switch management functions may be interrupted due to incorrect or outdated software when a switch takes over the primary management...

Страница 200: ...man agement module The slot 2 switch is the secondary A takeover is initiated by the user the primary management module is automatically reloaded Any data flow on the primary switch s Ethernet is int...

Страница 201: ...times To determine whether a stack is in need of synchronization use the show running directory command For example show running configuration CONFIGURATION STATUS Running CMM PRIMARY CMM Mode DUAL CM...

Страница 202: ...w chassis Displays basic configuration and status information for the switch chassis show cmm Displays basic hardware and status information for primary and secondary management modules operating in t...

Страница 203: ...wesentlichen Anforderungen und sonstigen Bestimmungen der Richtlinien 2004 108 EG EMV Richtlinie 2006 95 EG Niederspannungsrichtlinie 91 263 EWG Telekommunikationsendeinrichtungen falls zutreffend 199...

Страница 204: ...ubstance of at least one of all homogeneous materials in the parts is above the relevant threshold of the SJ T11363 2006 standard This table shows where these substances may be found in the supply cha...

Страница 205: ...ina RoHS Hazardous Substance Table OmniSwitch 6850 6850E Hardware Users Guide June 2011 page A 3 Products are packaged using one or more of the following packaging materials Corrugated Cardboard Corru...

Страница 206: ...UL 60950 1 2nd Edition 2007 03 27 CAN CSA C22 2 No 60950 1 07 2nd Edition 2007 03 EN 60950 1 2006 with Amendment II 2009 IEC 60950 1 2005 2nd Edition AS NZS TS 001 and 60950 2005 Australia UL AR Arge...

Страница 207: ...equipment It is suggested that the user use only shielded and grounded cables to ensure compliance with FCC Rules If this equipment does cause interference to radio or television reception the user is...

Страница 208: ...a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance...

Страница 209: ...nt trois fonctions importantes ils vitent tout risque de choc lectrique l int rieur du ch ssis ils font barrage aux interf rences lectromagn tiques susceptibles d alt rer le fonctionnement des autres...

Страница 210: ...ect il est recommand de ne pas regarder fixement l int rieur de ces ouvertures Installez les caches connecteurs pr vus cet effet Deutsch Die Laser strahlen an der Blenden ffnung unsichtbares Licht ab...

Страница 211: ...ement Warning To avoid shock hazard The power cord must be connected to a properly wired and earth receptacle Any equipment to which this product will attached must also be connected to properly wired...

Страница 212: ...Guide Deutsch Der Getting Started Guide welcher diese Anlage beiliegt enth lt wichtige Sicherheitsinformationen ber die sie sich beim Arbeiten mit den Hardwareeinheiten bewu t sein sollten Sie sollten...

Страница 213: ...Weil elektrostatische Aufladung ESD Teile der Anlage besch digen k nnten m ssen sie sich selbst erden bevor sie mit der Hardware Installation beginnen Zu diesem Zweck stellt Alcatel Lucent ein Erdung...

Страница 214: ...dvertencia de radiaci n l ser invisible Los lasers emiten radiaci n invisible de la apertura abierta cuando no se conecta ning n cable de fibra ptica Al quitar los cables no mire fijamente en las aber...

Страница 215: ...e restrinja el acceso Una ubicaci n con acceso restringido es una donde est seguro y limitado el acceso al personal de servicio que tiene un clave especial u otros medios de la seguridad Advertencia d...

Страница 216: ...Instrucciones de seguridad en espa ol Regulatory Compliance and Safety Information page A 14 OmniSwitch 6850 6850E Hardware Users Guide June 2011...

Страница 217: ...k mounting 2 60 rear panel 2 55 3 3 3 6 3 9 3 12 3 15 3 18 3 21 3 24 3 27 tabletop 2 59 chassis types OS6850 24 2 22 OS6850 24L 2 3 OS6850 24X 2 30 OS6850 48 2 26 OS6850 48L 2 7 OS6850 48X 2 34 OS6850...

Страница 218: ...iSwitch 6850 P48L OS6850 P48X see OmniSwitch 6850 P48X OS6850 U24X see OmniSwitch 6850 U24X P pass through modules 6 14 reloading 6 33 pinouts 2 70 3 34 PoE 5 1 defaults 5 5 monitoring 5 4 5 12 priori...

Страница 219: ...keover command 6 37 technical specifications console port 2 68 2 71 3 32 3 35 OmniSwitch 6850 24 2 24 3 4 OmniSwitch 6850 24L 2 5 OmniSwitch 6850 24X 2 32 OmniSwitch 6850 48 2 28 3 16 OmniSwitch 6850...

Страница 220: ...Index Index 4 OmniSwitch 6850 Series Hardware Users Guide June 2011...

Отзывы: