Open Problem Reports and Feature Exceptions
OmniSwitch 6800/6850/9000—Release 6.1.3.R01
page 53
PR 107284
Supplicant and non-supplicant are not displayed together on the same front page for 802.1x on an OS6850.
Workaround:
View the non-supplicants on a different page - 802.1x non supplicant page. Display Issue
Only.
PR 107315
A duplicate slot in a stack of switches will not display the switch picture in the WebView > Chassis Mgmt
> Chassis homepage.
Workaround:
Remove the duplicate slot.
PR 107529
WebView Networking > IP > BGP > Policy Route Maps Modify help "local Preference Value" hyperlink
is broken.
Workaround:
There is no known workaround at this time.
PR 107530
When using the Netscape browser to access the WebView > Policy > Policy > Ports page after clicking on
either "Previous" or "Next" buttons and then clicking on the "Refresh" button, a "method not allowed"
error is displayed.
Workaround:
Click on the "Ports" menu to refresh.
Autonegotiation
Problem Reports
PR 86826
On an OS6800/OS9000, when autonegotiation is disabled and speed is forced to 10 Mbps, copper ports
may confuse with a forced 100Mbps link partner and can detect a false link UP. Traffic may not pass in
this condition.
Workaround:
Enable autonegotiation for this copper port and configure desired speed and duplex
settings.
Layer 2