Installing the Cable Management System
Page 54
7750 SR-12
I
NSTALLING
THE
C
ABLE
M
ANAGEMENT
S
YSTEM
The 7750 SR-12 chassis can accommodate 2 optional cable management trays. The trays are
mounted horizontally on the front of the chassis, above and below the chassis card slots (card
cage).
The following instructions assume the chassis rack mounting brackets remain in the front-
mounting position, as they are shipped from the factory. The cable management trays are shipped
with shims screwed into the brackets. Remove the shims if the 7750 SR-12 chassis is front-
mounted.
The integral cable management tray mounting brackets align with mounting holes located on each
side of the chassis, above and below the card cage (
).
If the chassis rack mounting brackets are removed and relocated to accommodate a mid-mount
chassis installation, then a shim must be placed between each cable management tray mounting
brackets and the chassis wall. Shims fill the gaps between the chassis wall and the cable
management tray brackets that would otherwise be occupied by the rack mounting bracket (which
were removed and reinstalled at the mid-line).
Key 2 of
illustrates the cable management system installation with the chassis front
mounted in an equipment rack.
Key 3 of
illustrates the cable management system installation with the shim when the
chassis is mid-mounted in an equipment rack.
The cable pegs are accessed by flipping the upper access door upward and the lower access door
downward.
Mount the chassis in the equipment rack before installing the cable management trays.
Содержание 7750 SR-12
Страница 1: ...7750 SR 12 INSTALLATION GUIDE Document Part Number 93 0019 01 December 2003 ...
Страница 6: ...Page 4 7750 SR 12 Table of Contents ...
Страница 14: ...Page 12 7750 SR 12 ...
Страница 84: ...Monitoring AC Power Page 82 7750 SR 12 ...
Страница 100: ...Establishing Router Connections Page 98 7750 SR 12 ...
Страница 150: ...Impeller Trays Page 148 7750 SR 12 ...
Страница 156: ...Cable Pin Assignments Page 154 7750 SR 12 ...