![Alcatel 7750 SR-12 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/alcatel/7750-sr-12/7750-sr-12_installation-manual_2891366029.webp)
7750 SR-12 Overview
7750 SR-12
Page 27
DC P
OWER
E
NTRY
M
ODULES
DC PEMs are easily installed and removed from the rear 7750 SR-12 chassis power slots 1 and 2.
One PEM can support the full system current requirements if you are operating the SR-12 without
power redundancy. For redundancy, two PEMs must be installed and powered on at all times.
Always operate an energized chassis with the safety cover installed over the DC power terminal
block to prevent contact with hazardous voltages and currents and to prevent accidental removal.
Power cables are not included. You must provide power cables compliant with your local safety
codes. For information about preparing cables, refer to
DC-Input Power Wiring on page 69
There are no field replaceable parts on a DC PEM. The entire unit must be replaced in the event of
a failure.
Figure 4: SR-12 DC Power Entry Module
5
1
2
3
4
SR12003
Table 5: DC Power Entry Module Features
Key
Description
1
Power cable (VDC)
2
Return cable (RTN)
3
Safety cover
4
I
/ O (On/Off) switch (accessible without removing safety cover)
5
DB-25 connector (provides status if AC power is used)
Содержание 7750 SR-12
Страница 1: ...7750 SR 12 INSTALLATION GUIDE Document Part Number 93 0019 01 December 2003 ...
Страница 6: ...Page 4 7750 SR 12 Table of Contents ...
Страница 14: ...Page 12 7750 SR 12 ...
Страница 84: ...Monitoring AC Power Page 82 7750 SR 12 ...
Страница 100: ...Establishing Router Connections Page 98 7750 SR 12 ...
Страница 150: ...Impeller Trays Page 148 7750 SR 12 ...
Страница 156: ...Cable Pin Assignments Page 154 7750 SR 12 ...