Chassis Management and Fabric Modules
Installing CMM and CFM Modules
OmniSwitch 10K Hardware Users Guide
August 2015
page 3-5
Installing CMM and CFM Modules
Before installing CMM and CFM modules in the OmniSwitch 10K, locate their slot positions in the
chassis. Slot numbers are clearly marked on the OmniSwitch 10K front panel.
CMM modules may be installed in slots A and B. CFM modules may be installed in slots C and D.
Note.
If two CMM modules are installed in a chassis, the CMM occupying slot A is the
primary CMM by default.
To install an CMM or CFM module, follow the steps below:
1
Insert the module into the slot along the chassis card guides. The component side of the board should
face right. The module should slide in easily.
Note.
Do not force the module into the slot. If resistance is encountered, make sure the module is aligned
properly in the card guides.
2
When the module is nearly seated in the slot, be sure that the two extractor levers—one on top of the
module and one on the bottom—are open (approximately 90 degrees). This allows the notch on each
extractor lever to grasp the rail on the chassis.