DS1 cleanup procedures
Installation tests
4 - 1 8
365-372-304R7.1
Issue 1, November 2007
............................................................................................................................................................................................................................................................
DS1 cleanup procedures
Delete any existing DS1 cross-connections
Before moving on to the next port to test, it is necessary to remove the cross-connection.
This procedure details the necessary steps to delete a cross-connection.
........................................................................................................................................................................................................................
1
Select Configuration -> Cross-Connections...
........................................................................................................................................................................................................................
2
Use the Cross-Connection Wizard to Delete leg(s) of an existing cross-connection
associated with CP main-1, Port 1.
Requirement:
The DS1 test set should indicate a blue (AIS) signal is being received
in place of the QRSS signal.
........................................................................................................................................................................................................................
3
Remove the test set connections from the DSX-1.
........................................................................................................................................................................................................................
4
Select Configuration -> Update System... -> Update All.
Result:
This command will remove alarms generated by removing the test signals
from the DSX-1.
........................................................................................................................................................................................................................
5
Repeat the
DS1 terminating equipment loopback testing (p. 4-10)
or the
terminating equipment transmission testing (optical main OLIU) (p. 4-11)
procedure and
the
Delete any existing DS1 cross-connections (p. 4-18)
procedure to test each of the
remaining DS1 tributaries of the Function Unit. This is necessary in order to ensure that
the cabling of each port address is correct.
The table below lists the tributaries and cross-connections for all DS1s associated with a
function group.
When testing cabling for a Function Unit slot other than a, replace the
a
in each of the
addresses with the letter (
b
,
c
, or
d
) corresponding to the Function Unit slot under test.
Table 4-2
DS1 Cross-Connections
Tributary @ DSX-1
Cross-Connection
2
m-1-1-1-2,a-1-1-2
3
m-1-1-1-3,a-1-1-3
Содержание Data Multiplexer Explore 1665
Страница 8: ... Contents v i i i 365 372 304R7 1 Issue 1 November 2007 ...
Страница 12: ... List of figures x i i 365 372 304R7 1 Issue 1 November 2007 ...
Страница 16: ... List of tables x v i 365 372 304R7 1 Issue 1 November 2007 ...
Страница 24: ... About this document x x i v 365 372 304R7 1 Issue 1 November 2007 ...
Страница 168: ... 1665 Data Multiplexer 1665 DMX stand alone installation tests I I 2 365 372 304R7 1 Issue 1 November 2007 ...
Страница 250: ... Additional optical tests optional Installation tests 4 6 2 365 372 304R7 1 Issue 1 November 2007 ...
Страница 272: ... Final operations Operational tests 5 2 2 365 372 304R7 1 Issue 1 November 2007 ...
Страница 274: ... 1665 Data Multiplexer 1665 DMX ring setup and testing I I I 2 365 372 304R7 1 Issue 1 November 2007 ...
Страница 326: ... Cleaning pluggable optics modules Fiber cleaning B 1 4 365 372 304R7 1 Issue 1 November 2007 ...
Страница 408: ...I N 4 365 372 304R7 1 Issue 1 November 2007 Index ...