Circuit pack installation
Software download and circuit pack installation
3 - 8
365-372-304R7.1
Issue 1, November 2007
................................................................................................................................................
9
Attach the fiber bracket to the blank pack with the hardware provided.
Important!
The bracket must be positioned with the LC openings in the down
position.
................................................................................................................................................
10
If there are any FAULT LEDs on or flashing on any of the inserted circuit packs, press the
UPD/INIT pushbutton on the SYSCTL circuit pack.
Result:
The operation of the UPD/INIT pushbutton on the SYSCTL circuit pack will
update the system and should clear all standing alarms.
................................................................................................................................................
11
If FAULT LEDs remain lit on any of the inserted circuit packs, replace the respective
circuit pack.
................................................................................................................................................
12
Any other alarms will be cleared later on in this chapter.
................................................................................................................................................
13
Check off the appropriate box in
Appendix E, “Installation checklist”
.
........................................................................................................................................................
E
N D
O
F
S
T E P S
Содержание Data Multiplexer Explore 1665
Страница 8: ... Contents v i i i 365 372 304R7 1 Issue 1 November 2007 ...
Страница 12: ... List of figures x i i 365 372 304R7 1 Issue 1 November 2007 ...
Страница 16: ... List of tables x v i 365 372 304R7 1 Issue 1 November 2007 ...
Страница 24: ... About this document x x i v 365 372 304R7 1 Issue 1 November 2007 ...
Страница 168: ... 1665 Data Multiplexer 1665 DMX stand alone installation tests I I 2 365 372 304R7 1 Issue 1 November 2007 ...
Страница 250: ... Additional optical tests optional Installation tests 4 6 2 365 372 304R7 1 Issue 1 November 2007 ...
Страница 272: ... Final operations Operational tests 5 2 2 365 372 304R7 1 Issue 1 November 2007 ...
Страница 274: ... 1665 Data Multiplexer 1665 DMX ring setup and testing I I I 2 365 372 304R7 1 Issue 1 November 2007 ...
Страница 326: ... Cleaning pluggable optics modules Fiber cleaning B 1 4 365 372 304R7 1 Issue 1 November 2007 ...
Страница 408: ...I N 4 365 372 304R7 1 Issue 1 November 2007 Index ...