1000Base-F and 100Base-F fiber installation
Equipment and cable installation for 1665 Data Multiplexer
(1665 DMX)
1 - 9 2
365-372-304R7.1
Issue 1, November 2007
............................................................................................................................................................................................................................................................
1000Base-F and 100Base-F fiber installation
Description
This section describes how to route the optical fiber cables from the interconnecting
equipment (for example, an
LGX
®
optical fiber distributing frame) to the optical ports on
LNW63, LNW64, LNW67, LNW68, LNW70, LNW74 and LNW78 Ethernet circuit
packs. Multi-mode optical fiber is required for LNW67 (1000 Base-F), LNW70 (100Base-
F ports) and LNW74 (100 Base-F ports). Single-mode fiber is required for LNW68 (1000
LX), LNW70 (1000Base-F ports) and LNW78(RPR) circuit packs.
The optical fiber cables will be connected to the optical ports after the circuit packs are
installed.
Important!
The optical fiber cable is fragile and must be protected. The fibers should
be placed in a protective tube or channel, such as PVC tubing, or
PANDUIT
cable
channel, when running the cable from the 1665 DMX High-Capacity shelf to the cable
rack. The fibers should be placed in the cable rack in a protective channel with nothing
on top of them. Cable ties should NOT be used with the optical fiber cables.
Unterminated optical connectors may emit laser radiation. Do not view an unterminated
optical connector with optical instruments.
Invisible laser radiation when unterminated. Avoid direct exposure of the eyes to the
beam.
Important!
Prior to connecting the optical fiber cables, the fibers should be
examined to ensure that they are clean. See
for
recommended cleaning procedures.
Procedure
........................................................................................................................................................................................................................
1
Refer to the engineering job specification. Determine the function group (slot 1 only)
where the pack will be inserted. The LNW63, LNW64, LNW67, LNW68, LNW70,
LNW74 and LNW78 packs can be inserted into any of the function groups (slot 1)
including the growth slot (g1). In order to use the 10/100BaseT electrical ports on the
WARNING
Laser hazard
WARNING
Laser hazard
Содержание Data Multiplexer Explore 1665
Страница 8: ... Contents v i i i 365 372 304R7 1 Issue 1 November 2007 ...
Страница 12: ... List of figures x i i 365 372 304R7 1 Issue 1 November 2007 ...
Страница 16: ... List of tables x v i 365 372 304R7 1 Issue 1 November 2007 ...
Страница 24: ... About this document x x i v 365 372 304R7 1 Issue 1 November 2007 ...
Страница 168: ... 1665 Data Multiplexer 1665 DMX stand alone installation tests I I 2 365 372 304R7 1 Issue 1 November 2007 ...
Страница 250: ... Additional optical tests optional Installation tests 4 6 2 365 372 304R7 1 Issue 1 November 2007 ...
Страница 272: ... Final operations Operational tests 5 2 2 365 372 304R7 1 Issue 1 November 2007 ...
Страница 274: ... 1665 Data Multiplexer 1665 DMX ring setup and testing I I I 2 365 372 304R7 1 Issue 1 November 2007 ...
Страница 326: ... Cleaning pluggable optics modules Fiber cleaning B 1 4 365 372 304R7 1 Issue 1 November 2007 ...
Страница 408: ...I N 4 365 372 304R7 1 Issue 1 November 2007 Index ...