15. CFM
409
Display items in Example 1
Table 15-11:
Items displayed for failure information
Example 2
The following figure is an example of displaying detailed information about a CFM failure.
Figure 15-8:
Example of displaying detailed failure information
>show cfm fault domain-level 7 detail
Date 2009/03/21 12:00:15 UTC
MD:7 MA:1000 MEP:1000 Fault
OtherCCM : - RMEP:1001 MAC:0012.e220.11a1 VLAN:1000 Time:2009/03/21 11:22:17
ErrorCCM : -
Timeout : On RMEP:1001 MAC:0012.e220.11a1 VLAN:1000 Time:2009/03/21 11:42:10
PortState: -
RDI : -
MD:7 MA:1010 MEP:1011 Cleared
OtherCCM : -
ErrorCCM : -
Timeout : - RMEP:1001 MAC:0012.e220.22a1 VLAN:200 Time:2009/03/21 10:22:17
PortState: -
RDI : -
>
Display items in Example 2
Table 15-12:
Items displayed for detailed failure information
Item
Meaning
Displayed information
MD
Domain level
0 to 7
MA
MA ID number
Configured MA ID number
MEP
MEP ID
MEP ID for the Switch
Fault
A failure is being detected.
--
Cleared
A failure has been cleared.
--
Time
Time when a failure was
detected
The time when a failure was detected by the MEP.
If multiple failures have been detected, the time each failure was
detected is displayed.
yyyy
/
mm
/
dd
hh
:
mm
:
ss
year/month/day hour:minute:second
-
is displayed if the failure has been cleared.
Item
Meaning
Displayed information
MD
Domain level
0 to 7
MA
MA ID number
Configured MA ID number
MEP
MEP ID
MEP ID for the Switch
Fault
A failure is being detected.
--
Cleared
A failure has been cleared.
--
OtherCCM
Failure level 5
A CCM was received from
another MA.
Indicates that a CCM was received from the remote MEP
belonging to another MA.
On
: A failure was found.
-
: No failures were found.
Содержание AX6300S series
Страница 4: ......
Страница 10: ......
Страница 16: ......
Страница 24: ......
Страница 25: ...9 PART 2 Filters Chapter 2 Filters show access filter clear access filter ...
Страница 34: ......
Страница 49: ...3 Access List Logging 33 Notes None ...
Страница 80: ...4 QoS 64 Notes None ...
Страница 112: ......
Страница 148: ......
Страница 202: ......
Страница 242: ......
Страница 264: ......
Страница 294: ......
Страница 304: ......
Страница 332: ......
Страница 377: ...12 VRRP 361 Notes None ...
Страница 378: ......
Страница 388: ...13 IEEE 802 3ah UDLD 372 file in advance if necessary ...
Страница 390: ......
Страница 406: ......
Страница 436: ...15 CFM 420 Notes None ...
Страница 440: ...15 CFM 424 Notes None ...
Страница 466: ...16 SNMP 450 appears and the MIB cannot be acquired ...
Страница 483: ...467 Chapter 17 sFlow show sflow clear sflow statistics restart sflow dump sflow ...
Страница 490: ......
Страница 497: ...18 LLDP 481 Notes None ...
Страница 505: ...489 Chapter 19 OADP show oadp show oadp statistics clear oadp clear oadp statistics restart oadp dump protocols oadp ...
Страница 514: ...19 OADP 498 Notes None OADP is not configured OADP has not been configured Check the configuration Message Description ...
Страница 516: ...19 OADP 500 Notes None OADP is not configured OADP has not been configured Check the configuration Message Description ...
Страница 520: ......