10. Redundancy of BCUs, CSUs, and MSUs
283
redundancy force-switchover
Replaces the active system with the standby system in a redundant configuration.
Syntax
redundancy force-switchover
Input mode
User mode and administrator mode
Parameters
None
Example
The following shows an example of replacing the active system with the standby system in a
redundant configuration:
>redundancy force-switchover Press the
Enter
key.
Display items
None
Impact on communication
•
Some packets might be lost temporarily while the system is being replaced.
•
To reconfigure network information after the system is replaced, communication might be lost
temporarily.
Response messages
Table 10-3:
List of response messages for the redundancy force-switchover command
Message
Description
Can't accept command (Active BSU is nothing).
There is no active BSU.
Can't accept command (system is busy).
The command cannot be accepted (because the system is busy).
Re-execute the command later.
Can't execute this command in standby system.
This command cannot be executed on a standby system.
Can't execute.
The command could not be executed. Re-execute the command.
Now switchover executing.
The system is being switched.
Now synchronize executing.
The
synchronize
command is being executed. Re-execute the
redundancy force-switchover
command after the
synchronize
command completes.
Now, configuration discord.
Configurations for the active system and for the standby system do
not match.
Now, configuration file is editing.
The configuration file is being edited or synchronized. If it is being
edited, quit editing and then re-execute the command. If it is not being
edited, wait a while, and re-execute the command.
Note, however, that this message might be displayed temporarily if
the standby system is being started.
Now, configuration file is writing.
The configuration file is being saved or synchronized. If it is being
saved, re-execute the command after the configuration is saved. If it
is not being saved, wait a while, and re-execute the command.
Note, however, that this message might be displayed temporarily if
the standby system is being started.
Содержание AX6300S series
Страница 4: ......
Страница 10: ......
Страница 16: ......
Страница 24: ......
Страница 25: ...9 PART 2 Filters Chapter 2 Filters show access filter clear access filter ...
Страница 34: ......
Страница 49: ...3 Access List Logging 33 Notes None ...
Страница 80: ...4 QoS 64 Notes None ...
Страница 112: ......
Страница 148: ......
Страница 202: ......
Страница 242: ......
Страница 264: ......
Страница 294: ......
Страница 304: ......
Страница 332: ......
Страница 377: ...12 VRRP 361 Notes None ...
Страница 378: ......
Страница 388: ...13 IEEE 802 3ah UDLD 372 file in advance if necessary ...
Страница 390: ......
Страница 406: ......
Страница 436: ...15 CFM 420 Notes None ...
Страница 440: ...15 CFM 424 Notes None ...
Страница 466: ...16 SNMP 450 appears and the MIB cannot be acquired ...
Страница 483: ...467 Chapter 17 sFlow show sflow clear sflow statistics restart sflow dump sflow ...
Страница 490: ......
Страница 497: ...18 LLDP 481 Notes None ...
Страница 505: ...489 Chapter 19 OADP show oadp show oadp statistics clear oadp clear oadp statistics restart oadp dump protocols oadp ...
Страница 514: ...19 OADP 498 Notes None OADP is not configured OADP has not been configured Check the configuration Message Description ...
Страница 516: ...19 OADP 500 Notes None OADP is not configured OADP has not been configured Check the configuration Message Description ...
Страница 520: ......