10
WIRING
See the Installation Manual for more information.
Batteries:
Use only 1.5 volt Duracell Alkaline size-AA batteries.
With average use, batteries last about 5 years.
Terminals (Standard Models Only)
Red & Black Wires (Operation without Batteries) -
Optional 7.5 VDC Voltage for operation without batter-
ies.
White & White Wires (Remote Input) -
Wire a Nor-
mally Open Contact to Terminals 3 & 4. Momentarily
close to allow person to pass through door.
NOTE:
Re-
mote Input is enabled from the factory.
PC Interface -
Connect to Serial Port on Computer us-
ing A-PCI interface cable.
Wire Leads for DL2800WP Models
Note:
On all WP (waterproof) models, be sure to use
provided dielectric grease on the battery connector to
ensure a waterproof connection.
POWER DOWN
--RETAIN LOCK PROGRAMMING
•
When applying power to the lock for the first time
,
stop here and follow the procedure outlined in "QUICK
START" on page 6.
•
When power is re-applied to a lock that was already
operational and you wish to retain the lock program-
ming
(such as when transferring the lock from one door
to another door), proceed as follows:
1. Unplug battery pack.
2. Press any key to ensure the lock's capacitor is fully dis-
charged.
3. Re-connect battery pack (lock will give 3 short beeps).
4.
Do not press any keys for 10 seconds
.
5. After the 10 second period the LED will flash red 6
times and 6 beeps will sound.
The lock is now ready for use.
Program is loaded from
non-volatile (fixed) memory.
Note:
Audit Trail and Clock
Settings are lost. Re-set the clock using functions 38, 39
and 40.
ERASE ALL PROGRAMMING
•
The "out of box" factory default will be loaded.
1. Unplug battery pack.
2. Press any key to ensure lock's capacitor is fully dis-
charged.
3. Re-connect battery pack (lock will give 3 short beeps).
4.
Press any key within 5 sec after hearing the 3
beeps
.
5. A series of beeps will be heard.
All settings and programming have been erased and the
lock is now ready for use.
Note:
All lock programming can
also be erased (without need to disconnect the batteries)
by entering Function 99.
BATTERY REPLACEMENT
•
When applying power to the lock for the first time
,
stop here and follow the procedure outlined in "QUICK
START" on page 6.
You will know the batteries are weak when a valid
code is entered and the following occurs: the light
amber LED lights and the sounder sounds for 4 sec-
onds.
The DL2800 lock uses five (5) AA-size 1.5 volt
alkaline batteries. Always replace weak batteries as
soon as possible.
CAUTION: Do not press any keys while batteries are
disconnected or you may erase the real-time clock
settings.
Pressing any key will remove the voltage that
is required to keep the system clock and Audit Trail in
memory.
1. At the back of the lock, remove the screw at the bottom
of the lock housing and remove the cover.
2. Pull out the battery pack and quickly replace all 5 bat-
teries - within 2 minutes.
3. If you
do not
hear the 3 beeps when power is re-
applied, all programming and settings have been re-
tained, and the lock is ready for use. Go to step 5.
4. If you
do
hear 3 beeps when power is re-applied,
do
not press any keys for 15 seconds
. After the 15 sec-
ond period, the LED will flash red 6 times and 6 beeps
will sound. Reset the clock using functions 38, 39 and
40.
5. Replace the cover and tighten the screw.
Wiring, Power Up & Battery Replacement
WH
I
T
E
WH
I
T
E
BLACK
RE
D
BLACK
RE
D
Remote
Release
Battery
Connector
Motor
Connector
Содержание Trilogy DL2800
Страница 34: ...34 NOTES ...
Страница 35: ...35 NOTES ...