11
DL-Windows Programmable Functions
"Features" Screen -
Relay
tab
Select any of the relay functions below to activate the in-
tegral relay output (more than one may be selected).
Remote Input While Enabled
Activates relay when the Remote Input (two white wires
inside the rear housing) are momentarily shorted.
Provides an alert that access has been granted via the
Remote Input.
Remote Input While Disabled
Activates relay when the Remote Input wires (two white
wires inside the rear housing) are momentarily shorted
when the Remote Input is disabled. Provides an alert
that an unsuccessful access has been attempted via the
Remote Input.
Failed Entry Attempt
Activates relay if
any
unsuccessful proximity card entry
attempt occurs. Provides an alert that an unauthorized
proximity card entry attempt has been detected.
Disabled User Entry Attempt
Activates relay if a User presents their proximity card
while that proximity card is disabled. Provides an alert
that a disabled proximity card entry attempt has been
detected.
Authorized Entry
Activates relay anytime a User presents a valid proximity
card and is granted access.
Scheduled (Group 1 Activated)
Activates relay if the PL6600 / ETPLNRX has been
programmed for "Scheduled Relay Activation (Group 1
Initiated)" and a member of Group 1 has presented their
proximity card within the required window.
Locked by Schedule
Activates relay if the PL6600 / ETPLNRX has been
locked by a programmed schedule.
Unlocked by Schedule
Activates relay if the PL6600 / ETPLNRX has been
unlocked by a programmed schedule.
Any Key Press or Card Entry
Activates relay any time a proximity card is presented.
Relay follows Lock/Unlock Status
Activates relay when the PL6600 / ETPLNRX is
unlocked. Relay power must be provided from an exter-
nal power supply. If this option is selected, the relay re-
mains activated as long as the PL6600 / ETPLNRX is
unlocked. This feature supersedes all other relay options
except
Activate Relay on Door Ajar
and
Activate Relay
on Forced Door
.
Activate Relay on Door Ajar
If the door is held open (Door Contacts also open) for
longer then the allowed
Door Ajar Trip Time In Seconds
(programmed in the
Options
tab detailed on previous
page) the Aux Relay will engage for 2 seconds. See
"Door Ajar" in glossary.
Activate Relay on Forced Door
If the Door Contacts detect the door was opened without
a prior valid credential to unlock the unit, or the door was
opened without the inside lever first being turned (to acti-
vate the Lever Monitor Switch), the Aux Relay will en-
gage for 2 seconds. See "Forced Entry" in glossary.
Содержание Networx ETPLNRX
Страница 15: ...15 NOTES ...