35
1. The maximum permissible horizontal length of the flue system is:
3000mm. This length has to be considered 973 mm less for the use
of each additional 90° elbow.
2. The standard terminal must always be fitted horizontally. The flue
system must only terminate in a horizontal position. However 900
elbows may be used to drop the height of the flue system by 500 mm.
3. The flue system must use either a flanged elbow or a flanged eleva
-
tion duct at the entry / exit to the appliance.
4. All joints must be correctly made and secured in accordance with the
installation instructions in “Flue System Installation” section.
Refer to Figs. 15 & 16 to determine which flue options are required be
-
fore commencing the installation.