31
within 500 mm of painted eaves, then an aluminum shield at least 1000
mm long should be fitted to the underside of the gutter or painted sur
-
face.
The terminal should be fitted less than 2 meters above a surface to
which people have access.
In certain weather conditions a terminal may steam and sitting where
this could cause a nuisance should be avoided.
Take care to ensure that combustion products do not enter ventilated
roof voids.
Where elongation of the flue pipe is a necessary, only original extension
pipe and elbow must be used.
The flue system can be installed from inside the room without access
to the external wall and regardless of the wall thickness providing that a
suitable wall liner is fitted.
ATTENTION!
Flue terminal must be fitted with 3% downward inclination
to prevent rain leaking in to the boiler.