GETTING STARTED
There are six Device Types with preset parameters that
accommodate specific clinical applications. They are:
When setting up the pump, select the device type that best suits
your clinical needs. the abbreviated name of the Device Type
appears as a softkey on the Standard Display page. Pressing the
softkey displays the device type in non-abbreviated form on the
prompt line.
Maximum rate, maximum volume, pressure and air-in-line
threshold are configured at the factory. See
Table 1
for a
complete listing of preset parameters. Refer to the
C
Co
on
nf
fi
ig
g
softkey section for programmable and configurable parameters.
These parameters can be modified to meet the institution’s
specific requirements using FMS software.
1.
Press .
2.
Press .
•
T
To
ot
tV
Vo
ol
l
,
D
De
ev
vi
ic
ce
e
,
C
Co
on
nf
fi
ig
g
and
N
No
ot
te
e
softkeys appear.
3.
Press
D
De
ev
vi
ic
ce
e
softkey.
• The currently selected Device Type has an asterisk and is
highlighted.
4.
Press
S
Se
el
le
ec
ct
t
to move the highlight through the list.
5.
Press
E
En
nt
te
er
r
when the desired device is highlighted.
If preset values are compatible with the newly selected
device type,
• an asterisk appears next to the device name.
If channel is
not
infusing when device type is changed and
preset values are
not
compatible with the newly selected
device type,
• The display switches to a notification screen.
• Incompatible Channel(s) indicated.
• Choice is given to continue.
If
Y
Ye
es
s
,
• Incompatible values are cleared.
• Display reverts to Standard Display Page.
• New Device Type becomes active.
If
N
No
o
,
• Display reverts to Change Device Type page.
Device
NOTE:
The Device Type programming selection affects all three
channels. It is not possible to program different Device Types for
a channel independently.
To change Device Type
100
Stopped
ml/h
Device: General Purpose
STNDBY
VR: 450
VI: 50
GP
Cntrst
G
Ge
en
ne
er
ra
al
l
P
Pu
ur
rp
po
os
se
e
N
Ne
eo
on
na
at
ta
al
l
C
Co
on
nt
tr
ro
ol
ll
le
er
r
P
Pr
re
es
ss
su
ur
re
e
O
Op
pe
er
ra
at
ti
in
ng
g
R
Ro
oo
om
m
G
Ge
en
ne
er
ra
al
l
P
Pu
ur
rp
po
os
se
e
I
II
I
O
Op
pe
er
ra
at
ti
in
ng
g
R
Ro
oo
om
m
I
II
I
100
Infusing
Stop affects channel A
TotVol Device Config Note
VI: 50
ml/h
VR: 450
Operating Room
General Purpose
Change Device Type
Neonatal
Controller Pressure
Operating Room II
Press Stnd Display to Exit
Select
*
General Purpose II
Содержание MedSystem III
Страница 37: ...34 GETTING STARTED T H I S PA G E I N T E N T I O N A L LY L E F T B L A N K...
Страница 45: ...T H I S PA G E I N T E N T I O N A L LY L E F T B L A N K 42 ALARMS ADVISORIES AND PROMPTS...
Страница 61: ...58 MAINTENANCE T H I S PA G E I N T E N T I O N A L LY L E F T B L A N K...
Страница 63: ...T H I S PA G E I N T E N T I O N A L LY L E F T B L A N K 60 MAINTENANCE...