Fitting Supply Flow Sensor To Mixer Shower
Fit Flow Sensors between the
strainer and shower.
Allow enough distance so that
the sensors are easily accessible.
The Mixer shower has two supply lines – hot and cold water– fit
one flow sensor
to
each
line.
Install the filter which is a Y-Pattern strainer, in the correct position to the shower water supply
line(s) and then fit the flow sensor between the filter and the shower heater.
11
Flow
Direction
Shower
JG Push-Fit
Sensor Tail
CORRECT
POSITION
WRONG POSITION
CORRECT POSITION
Failure to install the Strainer may invalidate any warranty for the product.
Fit sensor using an approved liquid based thread sealant suitable for nylon threads.
Flow Sensor
Check Flow Direction
Sensor Cable
Shower
Strainer
All cable connections must be in a dry location.
Confirm
shower
water
supply
pipework
is
flushed
before
connecting
to
the
shower
sensor
via
the
strainer.
Any building debris in the water supply to the
shower heater will adversely affect the sensor
function and may also damage the shower
heater.
DO NOT tile over Flow Sensors
Sensor Cable
CHECK FLOW
SENSOR DIRECTION
FILTER IN WRONG POSITION
Flow
Sensor
Direction
Flow
Sensor
Direction
They must be accessible for servicing
CHECK FILTER POSITION
Flow
Direction
CHECK:
Direction of flow arrow moulded on casing is in the correct orientation.
Connect the sensor cables from the flow sensor to the pump (see electrical installation).
Ensure sensors and strainers are accessible for service and maintenance purposes.
Strainer
Flow
Direction
Flow
Direction
Vertical Hot & Cold Water Feed
Horizontal Hot & Cold Water Feed