Important Safety/Electrical Information
Ensure Mains Power Supply is Switched OFF before starting wiring.
The 230V AC power supply to this unit must be provided via a two-pole isolator
switch and a dedicated circuit with a 30mA RCD device installed in accordance
with the latest revision of the IEE Wiring Regulations BS7671. It must be wired into
a fused, unswitched, fixed wiring connector fitted with a 5 amp fuse.
The IP45 rating of the AKW pump product refers to the inner casing containing the
SELV electrical control gear. The pump motor which operates at SELV and is
located within the outer cover.
DO NOT
take risks with Plumbing or Electrical Installation. This product
must be installed and serviced by a competent and qualified person eg.
NIC EIC trades person should attempt this electrical installation in
accordance with the current edition of the Wiring Regulations (BS7671),
local by-laws and the current Building Regulations.
This product must be installed, used and maintained in good working
order in accordance with these instructions and recommendations.
THIS CLASS II APPLIANCE DOES NOT REQUIRE AN EARTH
Caution Danger of Death 230V AC
Lethal Voltage present on the AC supply.
3
If the supply cord is damaged, it must be replaced by the manufacturer
in order to avoid hazard.
ò+YPSS)P[Z
ò:\P[HISL^HSSWS\NZ
ò:JYL^KYP]LYZ
ò:WPYP[3L]LS
ò7PWLJ\[[LYZ1.;:
òTT7PWLHUKTT7PWL
ò1VOU.\LZ[SVJRPUNJVSSHYZ
Before you start...
Confirm you have the required tools and parts.
Standard JG pipe connectors
ARE NOT SUITABLE
for connecting to
CHR
OME
or
STAINLESS PIPEWORK
.
Chrome plating must be completely removed 20mm before JG fittings are
connected to pipework.
Always use Collet Clips provided
to ensure maximum grip.
It is not possible to connect JS fittings to Stainless Steel Pipe.
(2>9LJVTTLUK[OL\ZLVMH1VOU.\LZ[JOYVTLWPWLHKHW[VYWHY[UV