The electric shower has one supply line – cold water – fit
one flow sensor
to this line.
Install the filter which is a Y-Pattern strainer, in the correct position to the shower water supply
line and then fit the flow sensor between the filter and the shower heater.
Failure to install the Strainer may invalidate any warranty for the product.
Fit sensor using an approved liquid based thread sealant suitable for nylon threads.
FILTER IN WRONG POSITION
10
CORRECT
POSITION
WRONG POSITION
Strainer
Sensor Tail
Sensor Cable
JG Push-Fit
Shower
CORRECT POSITION
Strainer
Sensor Cable
Flow
Direction
Shower
Confirm
shower
water
supply
pipework
is
flushed
before
connecting
to
the
shower
sensor
via
the
strainer.
Any building debris in the water supply to the shower
heater will adversely affect the sensor function and
may also damage the shower heater.
All cable connections must be in a dry location.
DO NOT tile over Flow Sensors.
Flow
Direction
CHECK FLOW SENSOR DIRECTION
Fit Flow Sensors between the
strainer and shower.
Allow enough distance so that the
sensors are easily
accessible.
Flow Sensor
Check Flow Direction
DO NOT tile over Flow Sensors
They must be accessible for servicing
CHECK FILTER POSITION
Flow Sensor
CHECK:
Direction of flow arrow moulded on casing is in the correct orientation.
Connect the sensor cables from the flow sensor to the pump (see electrical installation).
Ensure sensors and strainers are accessible for service and maintenance purposes.
Flow
Direction
Flow
Sensor
Direction
Flow
Direction
Vertical Cold Water Feed
Horizontal Cold Water Feed