User Manual of Smart Digital Storage Oscilloscope
57
The description of
Pass/Fail
Menu
is shown as the follows:
Pass/Fail test:
Detect whether the input signal is within the limits of the rule, if it exceeds limits of
the rule, it is “Fail”, otherwise it is “Pass”. Also it can output fail or pass signal by
built-in, configurable and photoelectric isolation output port. To run the test, read the
following steps:
1.
Press
Utility
button, then
H1,
button turn the
M
knob to choose
Pass/fail
menu
option, Pass/Fail menu will be displayed in the bottom.
2.
Enable switch on
: Press
H2
button to show
Operate
menu, then, press
F1
button
to set
Enable
as
ON
.
3.
Create rule
: Press
H4
button to enter
Rule
setting menu. Press
F1
button to
choose the source; Press
F2
button, turn the
M
knob to set Horizontal tolerance;
Press
F3
button, turn the
M
knob to set Vertical tolerance; Press
F4
button to
create the rule.
4.
Set output type
: Press
H3
button to enter
Output
option setting. Choose any one
or two of the options “
Pass
”, “
Fail
” or “
Beep
”. “
Pass
” and “
Fail
” are mutually
exclusive options, which could not be chosen simultaneously. “
Stop
” means stop
once the condition satisfies your setting.
5.
Begin to test:
Press
H2
button, then
F2
button to select “
Start
”, the test will
begin.
6.
Save rule:
Press
H5
button, then
F2
button to save the rules, which could be
called up at once when need, press
F3
button to call up the rule saved.
Function Menu
Setting
Description
operate
Enable
Operate
Control enable switch
Control operate switch
Output
Pass
Fail
Beep
Stop
Info
Signal tested corresponds with the rule
Signal tested not correspond with the rule
Beep when it satisfies the rule
Stop once satisfying the rule
Control the display status of info frame
Rule
Source
Horizontal
Vertical
Create
Select source CH1
,
CH2 or Math
Change the Horizontal tolerance value by turning the
M
knob
Change the Vertical tolerance value by turning the
M
knob
Use the rule set as testing rule
Save Rule
Number
Save
Load
Choose any one from Rule1~Rule8 as your rule name
Click Save to save the rule
Load some rule as the testing rule