![Aktakom ADS2061 Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/aktakom/ads2061/ads2061_user-manual_2886799053.webp)
User Manual of Smart Digital Storage Oscilloscope
49
How to Save and Recall a Waveform
Press the
Save
button, you can save the waveforms and settings in the instrument.
The menu displayed in the screen is shown as
Fig.5-34
.
Fig.5-34
Waveform Save Menu
The description of the
Save Function Menu
is shown as the following table:
Function Menu
Setting
Description
Type
Wave
Setting
Image
Record
Choose the saving type (the
Record
Type
see “How to Record/Playback Waveforms”
on P51)
When the type is
Wave
, the menu shows as following:
Source
CH1
CH2
Math
Choose the waveform to be saved.
Object & Show
Object
1~15
Choose the address which the waveform is
saved to or recall from.
Show
ON
OFF
Recall or close the waveform stored in the
current object address. When the show is
ON, if the current object address has been
used, the stored waveform will be shown,
the address number and relevant
information will be displayed at the top left
of the screen; if the address is empty, “None
is saved” will be displayed.
Save
Save the waveform of the source to the
selected address. You can also press
Copy
button to do it. Storage format is vector.
Storage
Internal
External
Save to internal storage of USB storage.
When External is selected, save the
waveform according to the current record
length (see “
Record Length Menu
” on P42).
The file will be named according to the
current system time. The waveform file
could be open by
Aktakom
waveform
analysis software (on the supplied CD).
When the type is
Setting
, the menu shows as following: