1652H4A02 Ed.09
20
Control of defrost in standard mode
(
CE
=0)
Defrost start
Defrost will start if:
-The time programmed in parameter
d0
has elapsed since the start of the last defrost.
-We press the
H
key for 3 seconds.
-By means of an external push-button (
I10
/
I11
=5).
-Through the app or through AKONet.
Defrost completion
Defrost will complete if:
-The temperature programmed in parameter
d4
has been reached in probe 2. This requires a 2nd probe
(
l00
=2) to be available, located in the evaporator.
-The time configured in parameter
d1
has elapsed (maximum defrost duration).
-We press the
H
key for 5 seconds.
-By means of an external push-button (
I10
/
I11
=5).
-Through the app or through AKONet.
DEFROST
COLD REGULATION
COLD REGULATION
F4
Máx. d1
d3
d9
d0
SP
SP+C1
d4
DEFROST
DRIP TIME
FAN START-UP
DELAY
"DEF” MESSAGE
S1