Safety Considerations

1.  The safety guidelines in this manual are not intended to replace any rules 

or regulations or any applicable local, state, or federal governing laws.  
The following information is intended to be used in conjunction with other 

rules or regulations already in existence.  It is important to read all safety 

information before operating any wireless radio remote control system.

2.  Only properly trained persons designated by management should be 

permitted to operate wireless radio controlled equipment.  Wireless radio 
controlled equipment should not be operated by any person who cannot 
read or understand signs, notices and operating instructions that pertain to 
the equipment.

3.  Wireless radio controlled equipment should not be operated by any person 

with insufficient eyesight or hearing or by any person who may be suffer

-

ing from a disorder or illness or is taking any medication that may impair 
judgment or the ability to operate equipment.

4.  Ensure transmitter batteries are in good condition and power for receiver 

is correct.  Installation and maintenance should be done only while the con

-

trolled equipment main power and receiver’s power are off and locked out 
to prevent electrical shock.

5.  Any person operating wireless radio controlled equipment should possess 

the following knowledge and/or skills:

• 

Knowledge of hazards particular to the equipment being operated

• 

Knowledge of safety rules for radio controlled equipment

• 

Knowledge of the radio transmitter

• 

Proper clearance of all moving parts on the radio controlled equipment

• 

Proper storage space for radio control transmitter when not in use

• 

Transferring radio control transmitter to another person

• 

Reporting unsafe or unusual operating conditions

• 

Remote controlled equipment capacity and limitations

• 

Procedures for testing controlled equipment

6.  The Sesam remote control system is recommended for the remote opera-

tion of door opening equipment only. This unit is not intended for use on 
material handling, people moving or any other critical application. 

Содержание SESAM 800 K3

Страница 1: ...946415 000 A0 OPERATING MANUAL SESAM 800 K3 RX DIN USA...

Страница 2: ...er ________________________________11 7 Indicators on the receiver __________________________ 12 8 Configuration of the receiver ________________________ 12 8 1 Basic configuration____________________...

Страница 3: ...cope The following guide must be used when installing kerstr ms Sesam door opening system to ensure secure safe operation The installation must be car ried out by a certified electrician FCC Part 15 a...

Страница 4: ...or is taking any medication that may impair judgment or the ability to operate equipment 4 Ensure transmitter batteries are in good condition and power for receiver is correct Installation and mainten...

Страница 5: ...without checking door for obstructions 11 The equipment has been tested for correct operation before delivery from the factory However it must not be used in critical or hazardous operation where inc...

Страница 6: ...ust not be used in critical or hazardous operation where incorrect operation may cause personal or equipment damage 6 After daily operation a secure storage space should be designated for the transmit...

Страница 7: ...put 2 mW Functional sensitivity 107 dBm BER 10 4 Transmission principle GMSK TDMA Operating Temperature 25 C 55 C Storage Temperature 40 C 85 C Specifications RX DIN Power Supply 12 24V AC DC Max swit...

Страница 8: ...transmitters Designed for DIN rail 4 2 Transmitter This document covers transmitter model Sesam 800 Keyring K3 Miniature 3 button transmitter Suitable for controlling 3 non response time critical func...

Страница 9: ...together in pairs i e by using a cable binder very close to the terminal blocks Note that there might be hazardous voltage in the receiver therefore only certi fied electricians are allowed to open th...

Страница 10: ...ions on the receiver The receiver is equipped with connections for relays and power see fig 1 The connections for power connection are from left to right Line L Neutral N The connections for each rela...

Страница 11: ...D 7 Learn Indicates if the transmitter is in Learn Mode 8 Configuration of the receiver 8 1 Basic configuration 1 Open the lid on the receiver Open the lid of the receiver by pressing the snap fits on...

Страница 12: ...rder to activate relay two the status LED will flash twice c Press the Learn Erase button three times in order to activate relay three the status LED will flash three times 3 Press the button that sha...

Страница 13: ...tons 1 3 9 1 Indications on the transmitter Normal operation Quick flashing RED Sending message Continuous GREEN Relay activated in the receiver Feedback information from receiver Fault indications 3...

Страница 14: ...es note that changing of batteries must take place in a clean environment free from static electricity The batteries are changed as follows 1 Open the battery cover by unscrewing the 3 screws on the b...

Страница 15: ...s on the Status LED LED 6 regardless of fault ID already programmed Memory full Memory card mismatch during power up Memory card write error Maybe memory card has been removed during operation Memory...

Страница 16: ...str ms Bj rbo AB Box 7 SE 785 21 Gagnef Sweden street Bj rbov gen 143 SE 785 45 Bj rbo Sweden Phone 46 241 250 00 Fax 46 241 232 99 E mail sales akerstroms com www akerstroms com kerstr ms Bj rbo AB 2...

Отзывы: