43
AK-SecurePowerSwitch Manual,
Configuration
Settings :
First enter the IP addresses or the DNS names of the workings station which need to be
monitored under
“Target station”
. In this case it regards your working place computer.
You can enter the conditions in the bottom part of the page. Then, the
SecurePowerSwitch
checks if the working station indicated under
“Target station 5”
is
available or not. If the computer is available in the network, i.e. if it was switched on, then
the Condition2 applies and the power consumers will be switched on. If the computer is
switched off again, then the Condition1 applies and the power consumers will be switched
off again.
In order to check the function, the individual numbers of the conditions indicate the status
of the test in colours.
Green
:
The condition applies.
Yellow
:
The condition applies; the test is not completed yet.
Red
:
The condition does not apply.