AK-SecurePowerSwitch 

AK-SecureSocketSwitch 

Содержание AK-SecurePowerSwitch

Страница 1: ...Manual AK SecurePowerSwitch AK SecureSocketSwitch AK Nord GmbH Stormstrasse 8 D 25524 Itzehoe Germany Phone 49 0 4821 8040350 Fax 49 0 4821 4083024 AK SecurePowerSwitch AK SecureSocketSwitch...

Страница 2: ...ation 22 Changing the homepage 27 Replacing the firmware 29 SSL encryption 30 Encryption and certificate control 30 SSL encryption 31 Server certificate Server side certificate 31 Client certificate C...

Страница 3: ...ng devices by an interruption in the power supply 46 Settings 47 Application example 5 49 Switching electrical devices via the Internet 49 Registration 50 Configuration 51 Remote control with the PC v...

Страница 4: ...the 110 230VAC mains voltage Your electrical terminal is switched in only 10ms i e half a sinus wave To do so no electro mechanic relay but a fully electronic solid state relay is being used It partic...

Страница 5: ...The solid state relay is the actual switching relay and switches the electronic devices on or off 100ms before and 100ms after the switching operation the SSR relay is activated or deactivated It is...

Страница 6: ...ng receptacle C14 With switch and fusing 2 x RJ45 Mini Hub 1 x RS232 9Pol Sub D connector Ethernet AutoM DIX 10 Half Duplex 10 Full Duplex 100 Half Duplex 100 Full Duplex AutoSensing Network protocols...

Страница 7: ...g the switch for about 2 seconds Then 2 signal tones sound and the switch may be released It is possible to set the actuating period of the switch in the configuration menu 2 Status display These LEDs...

Страница 8: ...ng the smaller clips using a screwdriver Caution First switch off the device 3 110 230VAC input 4 110 230VAC output Note It is possible to use cables with inlet connectors for non heating apparatus IE...

Страница 9: ...oxyde contacts AgSnO2 offers you a high switching capacity a high level of durability as well as a reliable and trouble free operation The network connection is performed by default via a 1024Bit SSL...

Страница 10: ...lity and is mechanically reliable relay In particular the contact surfaces were additionally finished with AgSnO2 silver tin oxyde and therefore they have a little tendency to weld and a high burn off...

Страница 11: ...type F 1 x CEE 7 4 power input type F 2 x RJ45 mini hub Ethernet AutoM DIX 10 Half Duplex 10 Full Duplex 100 Half Duplex 100 Full Duplex AutoSensing Network protocols IPv4 TCP UDP FTP FTPS TFTP ICMP...

Страница 12: ...ion indicator Depending on the power consumption of the connected device the current power consumptions will be displayed with colours 2 Relay LED These LEDs indicate the following statuses On Indicat...

Страница 13: ...ble to achieve two functions 1 Factory Default function It allows resetting all values of the SecureSocketSwitch to factory settings This is done by plugging the SecureSocketSwitch into an outlet whil...

Страница 14: ...do not know the IP address you may also use the DNS name which is consisting of the AKIF and the last three digits of the MAC address when delivered The MAC address can always be found on the device...

Страница 15: ...you are requested to enter the user name and the password For safety reasons this page will be displayed until you have determined the user name and the password After having made all entries press th...

Страница 16: ...ta in real time and you will immediately get an overview of the consumption or the output of the connected electrical consumer Note The existing WEB interface can be replaced adapted or modified to th...

Страница 17: ...he subnet mask the DNS Host name as well as the DHCP procedures By clicking on Save these values are continuously saved in the SecurePowerSwitch Note As long as the DHCP is positioned on Y it is not p...

Страница 18: ...ime will fade in Note To do so it is necessary to connect the AK SecurePowerSwitch to the Internet RTC in preparation The current PC will be faded in Press the button Adopt and the time will be saved...

Страница 19: ...s well as the Timer Function do not block each other Mind possible overlapping in order that no unnecessary or uncontrolled switch processes are performed if you have programmed switch processes for b...

Страница 20: ...were triggered on which date at what time Possible entries WebService A switch function was triggered via the homepage Software A switch function was triggered via a TCP IP connection OverCurrent The...

Страница 21: ...on Here you can determine if the relay is automatically switched on after switching on M2M Account name Set up an account under www myopengate com and M2M Password enter the access data as well as th...

Страница 22: ...ut in the top menu and then click again on the button Monitor Then you will be asked to enter a user name and the password Do not use your standard user name but AKIF and the last three digits of the...

Страница 23: ...al Configuration Click again on the button Configuration in the top menu and then the button Expert Settings will be displayed Enter the special configuration menu of the SecurePowerSwitch by pressing...

Страница 24: ...the configuration menu Please find further information regarding the whole menu under http www ak nord de de daten handbuch_xxl_ts pdf Select I for INTERFACE MENU To do so enter an I into the input r...

Страница 25: ...ion Configuration menu Note In order to modify the value first enter the figure or the letter of the menu item the icon and then the new value Confirm your entry by pressing the button ENTER Then the...

Страница 26: ...SecurePowerSwitch will automatically switch off 6 Access password Setting the password for the TCP IP port The password only has to be transmitted if it has been configured accordingly If a password i...

Страница 27: ...e homepage In order to access the Flash File system of the SecurePowerSwitch enter e g ftp akif666666 in the Internet Explorer instead of http akif666666 You also have the option to use an FTP program...

Страница 28: ...or replace the existing homepage Note Make sure that the index file is always named index htm Always copy the SSL certificates or a new UPDATE on the root directory Volume1 For the update please first...

Страница 29: ...in the same way as for Changing the homepage But delete the directory HTML as well as the index htm and subsequently copy the update on the root directory Volume1 Then close the FTP Explorer and clic...

Страница 30: ...encrypted in any case and that it is not possible to read the content in the network However the Browser will always indicate an unsafe connection This is due to the reason that the browser Client obt...

Страница 31: ...l it on the SecurePowerSwitch Server To do so please proceed in the same way as for Modifying homepage and copy the certificate on the root directory Volume1 of the SecurePowerSwitch The certificate m...

Страница 32: ...If you create a certificate yourself e g by using the OPENSSL tool then you have to install the corresponding CA file using the public key on your browser Note If the certificate is edited by an offic...

Страница 33: ...33 AK SecurePowerSwitch Manual SSL encryption Restart the browser and then enter e g HTTPS AKIF666666 Your Browser will no longer indicate an unsafe connection...

Страница 34: ...Thus there is the option to allow access to the SecurePowerSwitch only to admitted or selected users via the browser via the encrypted TCP IP connection To do so it is possible to create a client cert...

Страница 35: ...to select a client certificate for the connection If your browser cannot prove this certificate or if you transfer the wrong certificate the connection will not be admitted Note If you do not want to...

Страница 36: ...ge via TCP IP Test program It is possible to test all control commands via the network using the PSW test program It includes the network protocols TCP and UDP and can be used under Windows It shows t...

Страница 37: ...0 PC can only be executed from version 1 7 6 Cmd Bytes Meaning Answers Bytes Meaning Protocol VER 5 Read version 1 0 5 Software version 1 0 UDP TCP TMP 5 Get temperature 27 ERR 29 5 27 Unknown 29 UDP...

Страница 38: ...u may additionally read the consumption data Execute an HTTP GET AK_PS XML req 64830 consumption 1 and you will additionally obtain CONSUMPTION xml version 1 0 encoding UTF 8 AK_PS IP 192 168 23 188 I...

Страница 39: ...od Execute an HTTP POST AK_PC XML and send the following XML data xml version 1 0 encoding UTF 8 AK_PC PCT 1 1 PCT AK_PC Examples PCT 1 1 PCT Off in 1 minute On in 1 minute PCT 15 5 PCT Off in 15 minu...

Страница 40: ...overnight unless they are not used and thus energy is consumed unnecessarily Example Departmental printers You have a department with 5 working places which access the same departmental printer If al...

Страница 41: ...able If all 5 working stations are no longer available the SecurePowerSwitch switches off the departmental printer The conditions 6 to 10 are used to check if one of the working stations was switched...

Страница 42: ...s working place printers monitors and other office machines are switched on overnight unless they are not used and thus energy is consumed unnecessarily Example Working place You have a working place...

Страница 43: ...icated under Target station 5 is available or not If the computer is available in the network i e if it was switched on then the Condition2 applies and the power consumers will be switched on If the c...

Страница 44: ...lamps etc are switched off at the end of the office hours Example Working place You have core working hours from 8 a m to 5 p m and your working place includes a PC monitor printer and a working place...

Страница 45: ...urs for each day of the week I e at what time the working place shall be supplied with power and when power shall be switched off Additionally enter as condition that the SecurePowerSwitch shall only...

Страница 46: ...dressed or if no function is available Example Router monitoring Sometimes no Internet connection is available In order to remedy this problem briefly switch the router off and on again The SecurePowe...

Страница 47: ...is no accidental switch function since the other server is still available If there is a failure of the router both servers are no longer available as described in this case This will then result in...

Страница 48: ...ches on again and the power supply is restored 6 It is waited for 2 minutes 7 The monitoring is restarted Note Enter a sufficient waiting time for Proceed ping After the interruption of the power supp...

Страница 49: ...evices via the Internet Example Controlling the SecurePowerSwitch via the Internet Network Power supply cord 110 230V Switching line 110 230V 110V 230V Network Internet ADSL Router 110V 230V Mobile h...

Страница 50: ...stration Register on the homepage http www myopengate com and follow the instructions on the homepage Note Do not use any special characters for the user name account name and the password and pay att...

Страница 51: ...tion These log in data are also stored there M2M Account name The user name assigned in MyOpenGate M2M Password The password assigned in MyOpenGate M2M Server Enter the rendezvous server here In this...

Страница 52: ...52 AK SecurePowerSwitch Manual Connection Remote control with the PC via the Internet Connect your device again under http myopengate com and log in your account with your M2M access data...

Страница 53: ...werSwitch Manual Connection Then select the Device list from the menu All devices connected to this account are displayed Then click on the corresponding device icon and you are immediately connected...

Страница 54: ...f course Since it is protected by access data you have to enter the user name and the password of the SecurePowerSwitch here refer to Determine password or Expert configuration Then you can switch the...

Страница 55: ...and log in with your user data Then click on the corresponding device icon and you are immediately connected to the device From now on you are directly connected to your SecurePowerSwitch e g at home...