background image

Operating principle

KeyPad Plus arms and disarms the security of the entire facility or separate
groups as well as allows activating the 

Night Mode

. You can control the security

modes with KeyPad Plus using:

11. 

 button 

Night mode

12. 

SmartBracket mounting plate (to remove the plate, slide it down)

Do not tear off the perforated part of the mount. It is required for actuating the
tamper in case of any attempt to dismantle the keypad.

13. 

Tamper button

14. 

Power button

15. 

Keypad QR Code

1. Codes

. The keypad supports general and personal codes, as well as arming

without entering a code.

2. Cards or key fobs

. You can connect 

 and 

 to the

system. To quickly and securely identify users, KeyPad Plus uses the

Tag key fobs

Pass cards

00:00

00:04

Содержание KeyPad Plus

Страница 1: ...urity mode with a LED light The keypad only works with and running OS Malevich 2 11 and higher Connection to and the and integration modules is not supported The keypad operates as part of the Ajax se...

Страница 2: ...nal elements 1 Armed indicator 2 Disarmed indicator 3 indicator Night Mode 4 Malfunction indicator 5 Pass Tag Reader 6 Numeric touch button box 7 Function button 8 Reset button 9 Arm button 10 Disarm...

Страница 3: ...move the plate slide it down Do not tear off the perforated part of the mount It is required for actuating the tamper in case of any attempt to dismantle the keypad 13 Tamper button 14 Power button 15...

Страница 4: ...ons if any The security status is displayed only when the keypad is active the device backlight is on DESFire technology DESFire is based on the ISO 14443 international standard and combines 128 bit e...

Страница 5: ...code KeyPad Plus supports duress code It allows you to simulate alarm deactivation The and installed at the facility will not give you away in this case but the security company and other users of the...

Страница 6: ...e loop zone can be found in Connection KeyPad Plus is incompatible with Hub third party security central units and ocBridge Plus and uartBridge integration modules Before starting connection Only a us...

Страница 7: ...in the Devices tab in the Ajax app Icon Value Jeweller signal strength Displays the signal strength between the hub or radio signal range extender and KeyPad Plus Battery charge level of KeyPad Plus 1...

Страница 8: ...ue Malfunction Pressing opens the KeyPad Plus malfunctions list The field is displayed only if a malfunction is detected Temperature Keypad temperature It is measured on the processor and changes grad...

Страница 9: ...splays the status of the ReX range extender use The field is not displayed if the keypad works directly with the hub Pass Tag Reading Displays if card and keyfob reader is enabled Easy armed mode chan...

Страница 10: ...name click on the pencil icon The name can contain up to 12 Cyrillic characters or up to 24 Latin characters Room Selecting the virtual room to which KeyPad Plus is assigned The name of the room is di...

Страница 11: ...ser codes Keypad code Selection of a general code for security control Contains 4 to 6 digits Duress code Selecting a general duress code for silent alarm Contains 4 to 6 digits Function button Select...

Страница 12: ...gh the Ajax app Auto lock Time min Selecting the keypad lock period after wrong code attempts Brightness Selecting brightness of the keypad buttons backlight The backlight works only when the keypad i...

Страница 13: ...Alarm option is selected for the Function button When the option is enabled the sirens connected to the security system give an alert when the button Function button is pressed Jeweller Signal Streng...

Страница 14: ...ability to create access codes for people who are not added to the hub This is convenient for example to provide a cleaning company with access to security management See how to set up and use each t...

Страница 15: ...ich 2 13 1 and higher Access codes are not supported by the Hub control panel Adding passes and tags KeyPad Plus can work with and third party cards and key fobs that use DESFire technology Before add...

Страница 16: ...eneral or personal codes and access codes configured by PRO or a user with admin rights The keypad allows you to use 4 to 6 digit codes Incorrectly entered numbers can be cleared with the button If a...

Страница 17: ...ect code is entered three times in a row within 1 minute The corresponding notifications are sent to users and to the monitoring station of the security company A user or PRO with administrator rights...

Страница 18: ...ase Night Mode can only be managed using a personal code if the user has the appropriate rights Security management of the facility using a personal code 3 Press the arming disarming Night Mode key 1...

Страница 19: ...sing an access code Enter the access code and press the arming disarming Night Mode key For example 1234 Security management of the group using a common code Enter the access code press the asterisk i...

Страница 20: ...duress code for people not registered in the system Scenarios and sirens react to disarming under duress in the same way as to normal disarming To use a keypad general duress code For example 4321 To...

Страница 21: ...he settings and the state of the system Keep in mind that the option is available only if is enabled 1 Activate the keypad by swiping your hand over it KeyPad Plus will beep if enabled in the settings...

Страница 22: ...changed by another device a key fob another keypad or an app You can activate the keypad by swiping your hand over the touch panel from top to bottom When activated the backlight on the keypad will t...

Страница 23: ...ght blink 3 times The batteries are low After changing the security mode the X LED lights up The touch buttons are locked for this time When you try to turn on the keypad with discharged batteries it...

Страница 24: ...ined by the distance from the hub or the radio signal range extender and the presence of obstacles between them that prevent the passage of the radio signal walls floors and other objects Be sure to c...

Страница 25: ...mmunication interferences Outdoors This could damage the device 1 Attach the keypad to the surface with double sided adhesive tape and carry out signal strength and attenuation tests If the signal str...

Страница 26: ...lus onto the mounting plate and tighten the mounting screw at the bottom of the body The screw is needed for more reliable fastening and protection of the keypad from quick dismantling 6 As soon as th...

Страница 27: ...e battery is low the system sends appropriate notifications and the X Malfunction indicator smoothly lights up and goes out after each successful code entry KeyPad Plus can work up to 2 months after t...

Страница 28: ...use not bound to the system pass tag Yes The keypad is locked for the time defined in the settings Radio communication protocol with hubs and range extenders Jeweller Radio frequency band 866 0 866 5...

Страница 29: ...rranty 24 months Warranty The warranty for the Limited Liability Company Ajax Systems Manufacturing products is valid for 2 years after purchase and does not extend to the bundled batteries If the dev...

Страница 30: ...Subscribe to the newsletter about safe life No spam Subscribe Email...

Отзывы: