Check the Jeweller Signal Strength at the installation site. If the signal strength is low (a
single bar) or zero, we cannot guarantee the stable operation of the security system.
Relocate the device, as repositioning even by 20 cm can signi cantly improve the signal
reception. If the detector still has a low or unstable signal strength after relocation, use a
Detection zone
Consider the operating area of the magnet when choosing the installation
location. Smaller magnets act at distances up to 1 cm from the reed switch,
while larger ones act at distances up to 2 cm.
When installing the detector, run a
. This allows you to
check the operation of the device and accurately determine the sector in which
the detector reacts to movement.
Do not install the detector
Detector installation
Before installing DoorProtect Plus, make sure that you have selected the optimal
Three bars
— excellent signal strength.
Two bars
— good signal strength.
One bar
— low signal strength, stable operation is not guaranteed.
Crossed out icon
— signal is missing.
1.
Outdoors. This can lead to false alarms and damage to the detector.
2.
Inside metal structures. This may result in the loss of the radio signal.
3.
Near mirrors. This may result in the shielding or attenuation of the radio
signal.
4.
In rooms with temperature and humidity out of the permitted operating
range. This may lead to the detector damage.