39
Emergency Heat. This mode activates the Auxiliary Heat to provide heated air in case of a mechanical failure in the system.
Note: This mode is only visible when the installation includes an auxiliary heating device.
User Mode. This parameter is only available when the Think thermostat is configured as main, the available modes are:
Comfort. Default and standard user mode. The desired set point temperature can be selected using the predefined
temperature ranges.
Eco. The range of available set point temperatures change for more efficient operation.
Night time. The system automatically changes the set point temperature 0.5º C/1º F every 30 minutes in up to 4 increments
of 2º C/4º F in 2 hours. When cooling, the system increases the set point temperature; when heating, the system decreases
the set point temperature.
Unoccupied. To be used when there is no presence detected for short periods of time. A more efficient set point
temperature will be set. If the thermostat is activated, the zone will start running in comfort mode.
Vacation. This mode feature saves energy while the user is away for extended periods of time.
Stop. The air-conditioning system will remain switched off regardless of the demand status of any zone, all the motorized
dampers will remain opened.
Airflow control. This parameter is only available when the Think thermostat is configured as main of a zoned system, selects
the control algorithm that best fits the installation. The available options are:
Silence. The fan speed is lower than in standard mode to reduce the noise.
Standard. Set by default. The system automatically regulates the fan speed based on the number of zones calling for
cooling or heating.
Power. The fan speed is higher than in standard mode to increase the flow.
Fan Speed. This parameter is only available on Fancoil installations, it is used to set the airflow control of the AC unit fan. The
airflow control is set in automatic mode by default, imposing the flow depending on the number of zones in demand.
High speed
Medium speed
Low speed
Low speed
Heating stages. This option is only available if the zone is configured as air+radiant configuration and enables to choose the
stage of the zone. The available parameters are:
Air. Only uses air stage.
Radiant. Only uses radiant air.
Air+radiant. The system combines both stages to reach comfort quickly and efficiently.
Note: For security reasons, the zone will turn off after changing any setting.
Local Ventilation. This option enables the activation
or deactivation
of the ventilation in the selected zone when the
system is not actively cooling or heating any of the zones.
Содержание AZVAF10KPROBE
Страница 1: ...r e b m u N e g a P d r a o b p il C Installation s Manual ...
Страница 2: ......
Страница 5: ...5 Navigation Trees 61 Blueface Thermostat Navigation Tree 61 Think Thermostat Navigation Tree 62 ...
Страница 34: ...34 Think Important In Think thermostats use to confirm and to return to the previous screen or menu ...
Страница 61: ...61 NAVIGATION TREES BLUEFACE THERMOSTAT NAVIGATION TREE ...
Страница 62: ...62 THINK THERMOSTAT NAVIGATION TREE Remember Use to confirm and for going back if browsing submenus ...