6
PRESSURE IS USUALLY SUFFICIENT TO
ACCOMPLISH THIS.
SOME OEM MODELS WILL BE EQUIPPED
WITH A PRE-INSTALLED POWER PLUG
ASSEMBLY WHICH IS NOT REQUIRED TO
PASS THROUGH AN ADDITIONAL STRAIN
RELIEF.
VII. INSTALLING THE 9630*451/9670*451
CEILING ASSEMBLY
See Figure 5
NOTE
The following step by step instructions must
be performed in sequence to insure a quick
and easy installation.
A. Remove the grilles and filters from the
ceiling assembly shroud.
B. Locate the cloth duct assembly and snap
the duct collar into place in the upper unit
basepan.
C. Raise the ceiling assembly chute to align
with the cloth duct assembly. Attach the
chute to the steel mount frame with the 4
short screws provided. Unfurl the cloth
duct to drop through the ceiling assembly
opening.
D. Gently peel off the release liner from the
VHB (Very High Bond) double sided tape.
Press the cloth duct uniformly around the
perimeter of the opening to adhere the
cloth duct to the plastic chute. Carefully
trim the excess cloth duct (a razor knife is
very effective for this).
E. Raise the shroud up near the mount
frame.
Plug in the communication cord from the
upper unit to the receptacle on the ceiling
shroud as shown in the magnified section
of Figure 5.
F. Align the shroud with the air chute insuring
that no wires are trapped between plastic
parts. Attach the shroud to the steel frame
with the 4 short screws provided.
G. Attach the room temperature sensor from
the upper unit to a middle hole of the steel
mount frame with the short screw
provided.
H. Replace the filters and retaining grilles.
Using the long screws provided, mount the
hand held remote control holster to an
interior wall at a height of 137 to 152 cm.
in a location withi
n “line of sight” to the
ceiling assembly sensor and will prevent
outlet air from the ceiling assembly to
affect the remote controller. Avoid
locations near heat producing appliances
or direct exposure to sunlight. This is
particularly important if using
the “follow
me” mode of the system in which the
temperature sensing will be by the hand
held remote instead of the sensor
mounted in the ceiling assembly return
airstream.
I. Install the batteries into the hand held
remote controller.
J. Restore power to the system.
This concludes the installation of the
system. The Operation & Maintenance
Instructions section of this manual
contains the operating and maintenance
instructions.