![Airwell DLS 30 DCI Скачать руководство пользователя страница 75](http://html.mh-extra.com/html/airwell/dls-30-dci/dls-30-dci_service-manual_2880105075.webp)
11-1
TUBING CONNECTIONS
SM DLSDCI 3-A.1 GB
11.
TUBING CONNECTIONS
TUBE (Inch)
TORQUE (Nm)
¼”
⅜”
½”
⅝”
¾”
Flare Nuts
15-18
40-45
60-65
70-75
80-85
Valve Cap
13-20
13-20
18-25
18-25
40-50
Service Port Cap
11-13
11-13
11-13
11-13
11-13
1. Valve Protection Cap-end
2. Refrigerant Valve Port (use Allen wrench to open/close)
3. Valve Protection Cap
4. Refrigerant Valve
5. Service Port Cap
6. Flare Nut
7. Unit Back Side
8. Copper Tube