![Airwell DLS 30 DCI Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/airwell/dls-30-dci/dls-30-dci_service-manual_2880105029.webp)
5-11
PERFORMANCE DATA & PRESSURE CURVES
SM DLSDCI 3-A.1 GB
5.3.3
Pressure Curves
(
Cooling – Technician Mode)
5.3.3.1 Cooling
DNG 80DCI - Cooling Test Mode Curves
Note: all temperatures are in C
0
.
22/15
Discharge Pressure VS. Outdoor Temp'.
1000
1250
1500
1750
2000
2250
2500
2750
3000
3250
3500
3750
4000
10
15
20
25
30
35
40
45
Outdoor DB Temperature[ºC]
Disch
arg
e
Pressu
re
[kPa]
22/15
24/17
27/19
29/21
32/23
Indoor DB/WB
Temp.
Indoor
DB/WB
Suction Pressure VS.Outdoor Temp'.
500
600
700
800
900
1000
1100
1200
1300
1400
10
15
20
25
30
35
40
45
Outdoor DB Temperature [ºC]
Su
ct
io
n P
re
ss
ur
e [
kP
a]
22/15
24/17
27/19
29/21
32/23
Indoor DB/WB
Temp.