Technical description
page 16
Dimension
Modul
Air flow rate
H x W x L
Weight
Output
Current rating
aereus®arco
Up to
600 cu m/h
540x350x550mm approx.
12kg
(aluminium)
160W 0,7A
Items supplied
•
aereus® arco
air purifier, ready to plug in
• User
guide
• 4x65 Allen key
4. Troubleshooting
Problem
Cause
Remedy
Device switches off
or won’t start
Main fuse
Examine, test voltage, replace if necessary
(electrician).
Switch on, test voltage, replace if neces-
sary (electrician).
Odour unchanged
High-voltage transformer not
connected or faulty
Test voltage, replace high-voltage trans-
former if necessary (electrician).
5.
Servicing and maintenance
5.1 Servicing
airtec competence GmbH will accept no warranty claims or liability for dam-
age caused by poor servicing!
Remove the mains plug before carrying out any servicing work on the
aereus® arco
!