10. CHECK LIST

]1

Pay special attention to the check items below when installing the indoor unit(s). After 
installation is complete, be sure to check the following check items again.

Check items

If not performed correctly

Check box

Has the indoor unit been in-
stalled correctly?

Vibration, noise, indoor unit may drop

Has there been a check for gas 
leaks (refrigerant pipes)?

No cooling, No heating

Has heat insulation work 
been completed?

Water leakage

Does water drain eas-
ily from the indoor units?

Water leakage

Is the voltage of the power source 
the same as that indicated on 
the label on the indoor unit?

No operation, heat or burn damage

Are the wires and pipes all 
connected completely?

No operation, heat or burn damage

Is the indoor unit earthed (grounded)?

Short circuit

Is the connection cable the 
speci

fi

 ed thickness?

No operation, heat or burn damage

Are the inlets and outlets 
free of any obstacles?

No cooling, No heating

Does start and stop air con-
ditioner operation by remote 
controller or external device?

No operation

After installation is completed, has 
the proper operation and handling 
been explained to the user?

11. ERROR CODES

1

If you use a wired type remote controller, error codes will appear on the remote controller 
display. If you use a wireless remote controller, the lamp on the photodetector unit will 
output error codes by way of blinking patterns. See the lamp blinking patterns and error 
codes in the table below.

Error indications

Wired Remote 

Controller Error 

code

Error contents

OPERATION 
lamp (green)

TIMER lamp 

(orange)

FILTER lamp 

(red)

 (1)

 (2)

Remote controller com-
munication error

 (1)

 (4)

Network communication 
error

 (1)

 (6)

Peripheral unit commu-
nication error

 (2)

 (6)

Indoor unit address set-
ting error

 (2)

 (9)

Connection unit number 
error in wired remote 
controller system

 (3)

 (1)

Indoor unit power supply 
abnormal

 (3)

 (2)

Indoor unit main PCB 
error

 (3)

 (10)

Indoor unit communica-
tion circuit (wired remote 
controller) error

 (4)

 (1)

Indoor unit room temp. 
thermistor error

 (4)

 (2)

Indoor unit heat ex. 
temp. thermistor error

 (5)

 (1)

Indoor unit fan motor 1 
error

 (5)

 (2)

Indoor unit coil (expan-
sion valve) error

 (5)

 (3)

Indoor unit water drain 
abnormal

 (9)

 (15)

Outdoor unit miscella-
neous error

 (13)

 (1)

RB unit error

Display mode 

  :  0.5s ON / 0.5s OFF

 

 :  0.1s ON / 0.1s OFF

 

( )  :  Number of 

fl

 ashing

Wired Remote Controller Display

Error code

UTY-RNKU (3-wire type)

UTY-RNRU (2-wire type)

Error icon

Touch the [Next Page] (or [previous page]) 
to switch to other indoor unit information.

2-digit numbers are corresponding to 
the error code in the preceding table.

For more information, refer to the installation manual of the remote controller.

Touch the [Status].

Touch the [Error Information].

9367701124-03_IM.indb   Sec1:16

9367701124-03_IM.indb   Sec1:16

2013-10-25   13:00:51

2013-10-25   13:00:51

Содержание ABUA12TLAV

Страница 1: ...nel only PART NO 9367701124 03 ABUA12TLAV ABUA14TLAV ABUA18TLAV ABUA24TLAV Fran ais MANUEL D INSTALLATION APPAREIL INT RIEUR type sol plafonnier Pour le personnel agr uniquement Espa ol MANUAL DE INST...

Страница 2: ...the outdoor unit down with bolts and a metal frame Provide a suitable air baffle In a Snowy Area for Heat Pump type Systems Install the outdoor unit on a raised platform that is higher than drifting...

Страница 3: ...dedicated tools and piping materials that have been manufactured specifically for R410A use Because the pressure of R410A refrigerant is approximately 1 6 times higher than the R22 failure to use ded...

Страница 4: ...use refrigerant leakage Area that can cause combustible gas to leak contains suspended carbon fibers or flammable dust or volatile inflammables such as paint thinner or gasoline If gas leaks and settl...

Страница 5: ...ccessories Special nut A Accessories Ceiling panel Spring washer Field supply M10 Nut Field supply M10 Nut Field supply 1 3 3 Installation the unit WARNING Install the air conditioner in a location wh...

Страница 6: ...48 F 120 C Reverse cycle model only In addition if the humidity level at the installation location of the refrigerant piping is expected to exceed 70 install heat insulation around the refrigerant pip...

Страница 7: ...iquid pipes Failure to do so may cause water leaks After checking for gas leaks insulate by wrapping insulation around the 2 parts Gas and Liquid of the indoor unit coupling using the coupler heat ins...

Страница 8: ...ctric shock or fire Before starting work check that power is not being supplied to the all units Use the included connection cables and power cables or ones specified by the manufacturer Improper conn...

Страница 9: ...37 to 90 Heat pump type indoor units Heat recovery type indoor units and RB units If the total number of units connected to the breaker exceeds 36 either add a 30mA breaker or use breakers with a grea...

Страница 10: ...emote controller cable Shielded wire no film 1 3 16 in 30 mm 1 15 16 in 50 mm Transmission cable Remote controller cable For 3 wire type For 2 wire type 1 3 16 in 30 mm 1 3 16 in 30 mm When the 2 cabl...

Страница 11: ...nd output cable with appropriate external dimension depending on the number of cables to be installed The wire connection should be separate from the power cable line Input select Use either one of th...

Страница 12: ...rning ON output to the connected external heater can be set by changing Dip switch on PC board Dip switch SET2 SW3 Fan setting when ON is output to the external heater Explanation OFF Factory setting...

Страница 13: ...s and the refrigerant circuit address can also be set up through the wireless remote controller Set it according to the following procedures when setting manually It can be set manually if the cover s...

Страница 14: ...er 02 Shorter Filter indicator action 13 00 Enable Enable or disable the filter indicator Setting 02 is for use with a central remote controller 01 Disable 02 Display only on central remote controller...

Страница 15: ...r lamp Orange FILTER indicator lamp Red MANUAL AUTO button 7 3 2 Checking the function settings Press and hold the MANUAL AUTO button on the indoor unit for 3 seconds to check the function settings It...

Страница 16: ...r plate Left 1 Join the cover plates left and mount with screws Tapping screw M4 10 mm Accessories Cover plate Left Accessories 8 4 Mount the intake grille 1 Cut the right side of the intake grille Th...

Страница 17: ...remote controller display If you use a wireless remote controller the lamp on the photodetector unit will output error codes by way of blinking patterns See the lamp blinking patterns and error codes...

Отзывы: