background image

  LIMITED WARRANTY

Hardware

AirScape warrants the original end user (“Customer”) that new AirScape Whole House fan products, 
including all moving parts, motors, dampers, and damper actuators will be free from defects in 
workmanship and materials, under normal use, for three (3) years from the original purchase date.

Software

AirScape warrants to Customer that the AirScape Whole House Fan software will perform in 
substantial conformance to its program specifications for a period of three (3) years from the date of 
the original purchase.

Exclusions

This warranty excludes (1) physical damage to the surface of the product, including cracks or 
scratches on the outside casing; (2) damage caused by misuse, neglect, improper installation, 
unauthorized attempts to open, repair, or modify the product, or any other cause beyond the range of 
intended use; (3) damage, caused by accident, fire, power changes, other hazard, or Acts of God; or 
(4) use of the product with any unauthorized device if such device causes the problem.

Exclusive Remedies

Should a covered defect occur during the warranty period and Customer notifies AirScape, Customer’s 
sole and exclusive remedy will be, at AirScape’s sole option and expense, to repair or replace the 
product. Replacement products or parts may be new or reconditioned or a comparable version of the 
defective item. AirScape warrants any replaced product or part for a period of ninety (90) days from 
shipment, or through the end of the original warranty, whichever is longer.

Obtaining Warranty Service

Customer must contact and return product to AirScape, Product dealer or Installer within the 
applicable warranty period to obtain warranty service. Dated proof of original purchase will be 
required. AirScape will not be responsible for Customer’s memory data contained in, stored on, or 
integrated with any products returned to AirScape for repair, whether under warranty or not.

Warranty Exclusive

The forgoing warranties and remedies are exclusive and in lieu of all other
Warranties, express or implied, including warranties of merchantability,
Fitness for a particular purpose, correspondence with description, and
Non-infringement, all of which are expressly disclaimed by AirScape and its suppliers.

Disclaimer

Neither AirScape nor its suppliers shall be liable for incidental, consequential, indirect, special, or 
punitive damages of any kind, or financial loss arising out of or in connection with the sale or use of 
this product, whether based in contract, Tort (including negligence) or any other theory, even if 
AirScape has been advised of the possibility of such damages AirScape’s entire liability shall be 
limited to replacement or repair of the product.

 

AirScape 2.5/2.5e WHF Installation Manual 02-11                                                                         Page 

15

Содержание 2.5

Страница 1: ...lation please verify that you received all the accessories with the whole house fan The packages should include BOX 1 of 3 damper door enclosure with grille IOM 8 metal and 4 wood screws 4 S hooks dua...

Страница 2: ...r 3 wire cable 20g or larger thermostat wire will work and electrical box for mounting wall switch Only if no other controller has been ordered with unit WHERE TO LOCATE Let s start with a little theo...

Страница 3: ...the total vent opening minus the loss caused by the interference of the screen louver or grille covering the vent The AirScape 2 5 2 5e requires a MINIMUM of 5 sq ft of net free venting area in your a...

Страница 4: ...much net free venting you have please consult a roofing professional Net free venting area can be acquired by any combination of gable eyebrow soffit or ridge vents or any other means that provide ven...

Страница 5: ...serted into the attic Please follow the instructions that apply to your install There is an existing attic access large enough for the 2 5 2 5e fan to fit through 16 O C Framing Step 1 Install two 14...

Страница 6: ...all cut out Approximately of each cross piece should be visible from below Figure 4 FIGURE 4 16 O C Framing 24 O C Framing Step 1 Cut a 23 x 14 opening in the dry wall use an existing joist as the 23...

Страница 7: ...sition Use the remaining screws to attach the opposite side of the damper box Use a good quality latex caulk to seal all wood to wood and wood to metal joints to create an airtight enclosure This is i...

Страница 8: ...the fan using the remaining sheet metal screws Figure 9 Finish by wrapping the joint with the provided tape to make the seam airtight The duct should be gently bent 90 degrees for maximum sound atten...

Страница 9: ...FIGURE 8 Hanging the Fan FIGURE 9 Duct to Damper and Duct to Fan Connections AirScape 2 5 2 5e WHF Installation Manual 02 11 Page 9...

Страница 10: ...the provided wall mounted double switch This 3 wire cable is NOT supplied with the unit but is widely available doorbell or thermostat cable is acceptable Step 2 Connect the control wiring with wire n...

Страница 11: ...FIGURE 11 Low Voltage Wall Switch Wiring FIGURE 12 Control Board Diagram AirScape 2 5 2 5e WHF Installation Manual 02 11 Page 11...

Страница 12: ...olt grounded outlet We do not recommend hardwiring the 2 5e fan power Verify that the 2 5 2 5e WHF power switch is OFF and turn on electrical power at circuit breaker Turn the unit ON in LOW speed The...

Страница 13: ...trol where the cooling effect is focused by which windows you open Visualize the path the air will take between the open windows and the unit Generally the longer the path the more overall cooling eff...

Страница 14: ...ing to the switch or remote Symptom Damper does not open Possible causes No power to damper actuator or damper shaft loose Suggestion Check power to unit and wiring The actuator actuator mounted termi...

Страница 15: ...w or reconditioned or a comparable version of the defective item AirScape warrants any replaced product or part for a period of ninety 90 days from shipment or through the end of the original warranty...

Страница 16: ...witch Decora style Supplied with unit Optional remote control available Remote and wall switch not supplied together Insulation R10 insulated damper doors Warranty 3 years 2 5 WHF Fan Energy Consumpti...