AirScape 2.5 Скачать руководство пользователя страница 13

  IMPORTANT OPERATING TIPS

 Only use it when the outdoor air is cooler than your indoor air.

 Make sure your A/C is off when you run the fan or you’ll be blowing expensive conditioned air 

       right out of your house!

 We recommend running your AirScape all night long. 

  Here’s why: The goal is to cool your entire house down, not just the air. It takes time to pull the   
  heat out of the structure and contents of a house. By ventilating all through the night, the house 
  starts the next day cooler so you can delay or eliminate running air conditioning the next day. 
  AirScape Whole House Fans are very energy efficient so running on low speed through the night 
  will only cost pennies.

 Use high speed to quickly cool down the house and low speed to run quietly through the night.

 Never operate the unit without opening a window – this can create negative pressure in the house 

       and cause dangerous back drafting with gas appliances.

 You can control where the cooling effect is focused by which windows you open. Visualize 

       the path the air will take between the open windows and the unit. Generally, the longer the path,  
       the more overall cooling effect. 

 If your home has a basement, extra cooling effect can be achieved by drawing air in through the 

  basement windows.

  MAINTENANCE

 There is no routine maintenance required for the 2.5/2.5e WHF other than to make sure that the 

  fan blades and damper are kept clean of any possible build up of lint or other debris. 

 Blocking the fan discharge during operation could cause premature fan failure if internal 

   temperatures rise to a very high level.  Ensure that no items are placed within 2 feet of the fan 
   discharge path. 

 A re-settable circuit breaker is located on the control box to protect the control board from power 

  surges. To reset, simply push the button back in.

  TIMECLOCKS – AUTOMATED CONTROLS

Please contact AirScape at 866.448.4187 or by email 

[email protected]

 for information on 

using a timeclock or other automated device with an AirScape Whole House Fan.

 

AirScape 2.5/2.5e WHF Installation Manual 02-11                                                                         Page 

13

Содержание 2.5

Страница 1: ...lation please verify that you received all the accessories with the whole house fan The packages should include BOX 1 of 3 damper door enclosure with grille IOM 8 metal and 4 wood screws 4 S hooks dua...

Страница 2: ...r 3 wire cable 20g or larger thermostat wire will work and electrical box for mounting wall switch Only if no other controller has been ordered with unit WHERE TO LOCATE Let s start with a little theo...

Страница 3: ...the total vent opening minus the loss caused by the interference of the screen louver or grille covering the vent The AirScape 2 5 2 5e requires a MINIMUM of 5 sq ft of net free venting area in your a...

Страница 4: ...much net free venting you have please consult a roofing professional Net free venting area can be acquired by any combination of gable eyebrow soffit or ridge vents or any other means that provide ven...

Страница 5: ...serted into the attic Please follow the instructions that apply to your install There is an existing attic access large enough for the 2 5 2 5e fan to fit through 16 O C Framing Step 1 Install two 14...

Страница 6: ...all cut out Approximately of each cross piece should be visible from below Figure 4 FIGURE 4 16 O C Framing 24 O C Framing Step 1 Cut a 23 x 14 opening in the dry wall use an existing joist as the 23...

Страница 7: ...sition Use the remaining screws to attach the opposite side of the damper box Use a good quality latex caulk to seal all wood to wood and wood to metal joints to create an airtight enclosure This is i...

Страница 8: ...the fan using the remaining sheet metal screws Figure 9 Finish by wrapping the joint with the provided tape to make the seam airtight The duct should be gently bent 90 degrees for maximum sound atten...

Страница 9: ...FIGURE 8 Hanging the Fan FIGURE 9 Duct to Damper and Duct to Fan Connections AirScape 2 5 2 5e WHF Installation Manual 02 11 Page 9...

Страница 10: ...the provided wall mounted double switch This 3 wire cable is NOT supplied with the unit but is widely available doorbell or thermostat cable is acceptable Step 2 Connect the control wiring with wire n...

Страница 11: ...FIGURE 11 Low Voltage Wall Switch Wiring FIGURE 12 Control Board Diagram AirScape 2 5 2 5e WHF Installation Manual 02 11 Page 11...

Страница 12: ...olt grounded outlet We do not recommend hardwiring the 2 5e fan power Verify that the 2 5 2 5e WHF power switch is OFF and turn on electrical power at circuit breaker Turn the unit ON in LOW speed The...

Страница 13: ...trol where the cooling effect is focused by which windows you open Visualize the path the air will take between the open windows and the unit Generally the longer the path the more overall cooling eff...

Страница 14: ...ing to the switch or remote Symptom Damper does not open Possible causes No power to damper actuator or damper shaft loose Suggestion Check power to unit and wiring The actuator actuator mounted termi...

Страница 15: ...w or reconditioned or a comparable version of the defective item AirScape warrants any replaced product or part for a period of ninety 90 days from shipment or through the end of the original warranty...

Страница 16: ...witch Decora style Supplied with unit Optional remote control available Remote and wall switch not supplied together Insulation R10 insulated damper doors Warranty 3 years 2 5 WHF Fan Energy Consumpti...

Отзывы: