- 23 -
Main Switch Base Assy. (Continued)
1. Put Hex. Nuts 1-3 in an Electrode Block, and fix a harness (red) coming from the Main Switch Unit
and an Electrode Plate to the notched side with a Hex. Bolt 3 x 8.
Likewise, fix a harness (black) coming from a Sub-board and an Electrode Plate to the non-notched
side with a Hex. Bolt 3 x 8. (Tightening torque: 80-100 cN.m)
Pay heed to the position of the notch in the Electrode Block and the relevant wire color. If the wire is
connected to the other side, the Main Board Unit will be broken.
2. Locate the terminals connected as shown in the figure.
ASSEMBLY PROCEDURE
TORQUE ADHESIVE
80-100 cN.m
Not required
Locate the terminals as
shown in the figure.
Notch
HARNESS
(BLACK)
(SUB-BOARD)
RB10970
(ELECTRODE BLOCK)
CC41104
(HEX. NUT 1-3)
HARNESS
(RED)
(MAIN
SWITCH)
BB40410
(HEX. BOLT 3 X 8)
RB11769
(ELECTRODE
PLATE)