- 20 -
Self-warm-up program
When the RB650/RB655 tool is used under cold temperature (below 0ºC/30F), you may find
the following phenomenon.
A. The part that catches the tie wire does not fully open after the tying action is completed,
and it is hard to pull out the tool from the tied wire.
B. The tie wire is not cut.
The self-warm-up program is installed to the RB650 and RB655. Running the self-warm-up
program helps to solve the phenomenon above.
How to run the self-warm-up program
Step 1.
Turn the main switch off and remove the tie wire from the tool.
Step 2.
Set the Torque dial at position “8” (maximum position).
Step.3
Keep pulling the Trigger and turn the Power switch on. The twisting
part of the RB650/RB655 automatically starts 50 times of twisting
action then stops.