- 47 -
Arm A Assy (Continued)
1. Apply Molykote PG-662 Grease to a Wire Guide Lever.
2. Put the Wire Guide Lever in between an Arm A Unit and a Wire Guide.
3. After degreasing a Hex. Screw 3 x 3, apply Loctite Blue to it to tighten to a Wire Guide Base.
(Tightening torque: 20-30 cN.m)
4. Tighten further a Hex. bolt 3 x 5 temporarily secured to the Wire Guide Base.
(Tightening torque: 150-200 cN.m)
Note) Wipe off overflowing adhesive agent.
ASSEMBLY PROCEDURE
TORQUE ADHESIVE
20-30 cN.m
Loctite Blue
150-200 cN.m
Not required
Tighten further in order to
and
.
IMPORTANT NOTE
(
RB10740
(WIRE GUIDE LEVER)
GREASE
MOLYKOTE PG-662
ARM A UNIT
Degrease before applying
Loctite.
IMPORTANT NOTE
(
AA71408
(HEX SCREW 3 x 3)
Tighten further
BB40481
(HEX BOLT 3 x 5)
IMPORTANT