1. Connect the hose and gun.
a.
Remove the plastic cap plug from the outlet tee
and screw a conductive or grounded 3000 psi
airless spray hose onto fluid outlet.
b.
Connect an airless spray gun to the other end of
the hose.
c.
Do not use steel braided airless hose. Use nylon
braided airless hose only.
NOTE:
Do not use thread sealer on swivel
unions as they are made to self-seal.
Use thread seal on
tapered male threads only.
3. Check the electrical service.
Be sure the electrical service is 120 VAC, 15 amp
minimum, and that the outlet you use is properly
grounded.
NOTE:
*For Generator power, a minimum 7000 watt
generator with voltage regulation must be used.
4. Grounding
2. Fill the packing nut/wet cup with
5 drops of Airlessco Throat Seal
Oil (TSO).
See (Figure 4).
5. Flush the sprayer
As per "Flushing Procedure" in this manual.
WARNING
To reduce the risk of static sparking, fire or
explosion which can result in serious bodily
injury and property damage, always ground
the sprayer and system components and the
object being sprayed, as instructed in the
safety warning section of this manual.
FIGURE 4