4.0 TESTING AND SETUP
4.1.
Introduction
Now that the installation is complete and you have complied with the wiring and cabling
requirements of this manual (800-10680-C), perform a final check of the Direct Current (DC)
power input connections to the AirCell
®
ST 3100 system. Verify that ground and 28 VDC
connections to the unit are correct and on the proper pin numbers. This will ensure confidence
when you apply power to the unit for the first time. After verifying that the DC power inputs are on
the proper power pins, pull open the circuit breaker and connect the power cable to the AirCell
®
ST 3100 Transceiver. Close the circuit breaker.
CAUTION
Before disconnecting or reconnecting AirCell
®
ST 3100 system components, pull open the power
circuit breaker to avoid damage to the AirCell
®
ST 3100 system components or the aircraft wiring.
4.2.
Testing
It is advisable to test the system to verify its proper operation. To test the system, place a call on
the Satellite network.
Operational testing of the AirCell
®
ST 3100 System should be accomplished in accordance with
test procedures outlined in this Installation Manual, Sections 4.6. and 4.7. Complete the required
paperwork to activate the system.
For Iridium telephone activation, be sure that the
Subscriber Service Agreement (SSA) have been properly filled out and faxed to AirCell
®
Customer Service @ 1-888-398-1800.
When the system has passed the operational test, verify that all Handsets are operational and
can be used at the same time, as in a conference call. Include for the aircraft records all cable
certifications, wire marking data, special diagrams used for the installation
.
Be sure to include the
SSA in the documentation paperwork for the aircraft. This insures that the owner has a record of
the installed serial numbers and corresponding phone number and electronic serial numbers.
4.3.
Test Equipment
No special test equipment is required to determine the operational status of the ST 3100 system.
4.4.
Test Results
Documentation of the test results is important for the aircraft Owner. All paperwork, special
drawings, cable routings, and special installation procedures should be included for the aircraft
records.
Testing and Setup
Page 4-1
Section 4
800-10680-C, May 2007
Содержание ST 3100
Страница 11: ...This Page Intentionally Blank Introduction Page 1 4 Section 1 800 10680 C May 2007...
Страница 21: ...This Page Intentionally Blank Installation Procedures Page 3 6 Section 3 800 10680 C May 2007...
Страница 29: ...This Page Intentionally Blank Testing and Setup Page 4 8 Section 4 800 10680 C May 2007...
Страница 31: ...Cleaning Page 5 2 Section 5 800 10680 C May 2007 This Page Intentionally Blank...
Страница 33: ......
Страница 34: ......
Страница 35: ......
Страница 36: ......
Страница 37: ...This Page Intentionally Blank Fits and Clearances Page 6 2 Section 6 800 10680 C May 2007...
Страница 41: ...This Page Intentionally Blank System Specifications Page 7 4 Section 7 800 10680 C May 2007...
Страница 43: ...This Page Intentionally Blank Special Tools Fixtures and Equipment Page 8 2 Section 8 800 10680 C May 2007...
Страница 45: ...This Page Intentionally Blank Illustrated Parts List Page 9 2 Section 9 800 10680 C May 2007...
Страница 47: ......
Страница 48: ......
Страница 49: ......
Страница 50: ......
Страница 51: ......
Страница 52: ......
Страница 53: ......
Страница 54: ......
Страница 55: ......
Страница 56: ...Wiring Diagrams Section 10 Page 10 2 800 10680 C May 2007 This Page Intentionally Blank...