P A R A M E T E R R E F E R E N C E ( T D M 8 8 0 I S P E C I F I C P A R A M E T E R S )
Parametrization of Tracking feature
Figure 6 Tracking configuration
In TPT configuration, the user can enable/disable the feature, select track storage size, default SDS intervals on
track transmission, and both the time and distance triggers for collecting location information into track.
AT interface
Parametrization of the Tracking functionality:
Table 8
Tracking parametrization: AT interface
SDS interface
Parametrization of the Tracking functionality over an SDS message requires that the message format presented
below is used.
Table 9
Tracking parametrization: SDS interface
DESCRIPTION
COMMAND
RESPONSE
Configuration
+CXGTSP=<Password>,<Tracking
enabled>[,<Max amount of entries>,<SDS
interval>,<Timer trigger>,<Distance trigger>]
OK, ERROR
Read configuration
+CXGTSP?
FIELD
TYPE
Protocol Identifier
SDS_TL_GENERAL_OTA_ID
Sub-protocol Identifier
SDS_TL_GTS_OTA_ID
PDU Type
4 bits : 0000
Tracking Enabled
4 bits : 0000 = disabled, 0001 = enabled
SDS Sending interval
8 bits : interval in seconds
Max amount of entries
16 bits : value range 200>=n<=500
padding
8 bits
padding
8 bits
Time trigger
32 bits : 0 = disabled, >0 = trigger interval in minutes
Distance trigger
32 bits : 0 = disabled, >= distance change in meters