Page 15
Air Techniques, Inc.
4.2.4 Change of filter for membrane dryer
Change the Sintered and fine filter in a clean ambient environment according to Figures 8 and 9 once a year.
4.3
Repairs
Attention!
Repair work can only be carried out by qualified and authorized specialists.
Attention!
Only use the spare parts and accessories permitted by the manufacturer. The
use of spare parts and accessories other than the ones stated in the manual could cause
injury to you.
Attention!
Before starting repair work, the compressor station must be separated from the
power supply (pull out the plug) and all lines must be depressurized.
If the necessary spare parts are not available the compressor station must be sent to the manufacturer for repair.
Figure 9.
Change of Fine or Sterile Filter
Note:
Membrane Dryer is shipped with a fine filter.
A sterile filter is an option.
5
Shutdown and Disposal
If the product is not in operation over a longer period, it is recommended to drain off the condensation from the
pressure receiver until the switch-off pressure is achieved. Thereafter open the drain plug until the condensation
stops leaking. Afterwards cut-off the machine from the pressure switch, close the condensation drainage and pull
out mains plug, depressurize the machine and pressure hoses.
The disposal has to be carried out in an appropriate way. The national laws and stipulations have to be followed.
For further questions please contact Air Techniques.
Shutdown and Disposal
Maintenance