1. 

INTRODUCTION AND GENERAL ADVICE

1.1  

Symbol explanation and definition

1.1.1   Symbol explanation

In the manual and on the product hand symbols and pictograms are used whose meaning you should memorize. 

These symbols help you to understand the information in this manual quicker and make you aware of potential 

danger or important advice.

 

Attention!

 Danger sign. It points out danger as well as 

rules and bans to prevent personal and /or danger to 

property.

 

Advice! 

Attention is brought to advise on the handling 

and economic use of product.

 

Warning against electric energy! 

Your life could be in 

danger. Make sure that all electrical work is carried out 

by a qualified electrician.

Warning  advice.  The  product  can  start  without 

warning!

On the product and in the operating instruction special information 

signs and warning Symbols with following meaning are used:

 

Warning of hot surfaces!

 There is a danger of burns! 

Observe especially that these surfaces may still be 

hot after the product has been switched off. Work near 

these surfaces only after they have cooled off.

1.1.2  Definitions

User, Operator: The responsible person who has the authorization to use the product. The user must have been 

given instructions on the safe handling of the unit from the appropriate authority.

Operator Authority:

 Responsible for the safe installation, regular servicing and cleaning of the product.

Qualified personnel: 

Trained by the operating authority or by authorised Air Techniques personnel who are aware 

of the dangers of the product and familiar with the technical aspects of the product. Qualified personnel are trained 

to carry out service and repair on the product.

Product: 

General term used for oil-free compressor stations.

1.2 

General safety advice

During use, care and maintenance of the product, the following fundamental safety measures must be observed for 

the protection of the operator, maintenance and service engineers as well as the product:

During the development and manufacture of the product, the recognized regulations of the technical 

aspects, as well as the recognized valid standards and guide-lines were taken into account and used. 

In addition the product has been designed and constructed in such a way that endangerment through 

the agreed use are minimized. Nonetheless we feel obliged to describe the following safety measures 

so the remaining dangers can also be minimized.

 

Warning!

 When electrical equipment is being used, the basic safety precautions must be followed, to 

prevent risk of fire, electric shock and personal injury.

 

Therefore please read the manual prior to starting work. Keep this manual within reach for the engineer 

and the operator. The information should be passed on to any successor.

Introduction and General Advice 

Содержание AERO100

Страница 1: ...AERO100 AERO100M AERO200 AERO200M OPERATING INSTRUCTIONS AERO200M...

Страница 2: ...nical information Qualified personnel This operating manual is valid for oil free compressor stations hereinafter called product The operating manual is only valid so long as your product complies wit...

Страница 3: ...trical installation 9 2 3 4 Motor protection 9 2 3 5 Circuit diagram 10 2 4 Initial operation 10 3 Operation 11 3 1 Switching on the product 11 3 2 Switching off the product 11 3 3 Switching on the pr...

Страница 4: ...ate authority Operator Authority Responsible for the safe installation regular servicing and cleaning of the product Qualified personnel Trained by the operating authority or by authorised Air Techniq...

Страница 5: ...trical components and if they are damaged have them repaired by a qualified electrician Check the electrical equipment for external damage before work starts Check thoroughly whether lines or cables a...

Страница 6: ...ompressed air until the set shut off pressure of 7 bar is indicated in the pressure switch 3 before switching off The tank pressure is indicated by the pressure gauge 9 Pressure is re leased in the pr...

Страница 7: ...the membrane fibres thereby the water molecules contained in the air diffuse through the membrane wall and accumulate outside of the fibre The dried air flows now via the fine filter the relief valve...

Страница 8: ...oduct must only be installed and operated in dry well ventilated and dust free rooms Take care when choosing the site for installation that the product is easily accessible for operating cleaning and...

Страница 9: ...ng system If the equipment is hard wired to the power supply a switch arrangement must be arranged with at least a 3 mm wide contact opening e g heavy duty switch If the product is connected to the po...

Страница 10: ...re switch is off Check the connections are correct to the compressed air components Make sure the machine is correctly connected to the power supply Check that the air filter is correctly fitted Switc...

Страница 11: ...duct Switch off the product to setting 0 OFF 3 3 Switching on the product after a power supply interruption Advice The product will not start against pressure Therefore the products are fitted either...

Страница 12: ...pressure reducer By slightly lifting the regulator knob 1 the constant pressure can be altered Increase pressure by rotating the regulator knob clockwise or decrease pressure by turning the regulator...

Страница 13: ...me working conditions e g long work times under full load high ambient temperature very dusty atmosphere high humidity the maintenance intervals will need to be shorter When carrying out maintenance w...

Страница 14: ...unterclockwise until the bayonet lock is closed again Attention Never clean filter inserts with petrol or oil 4 2 3 Check safety valve function The safety valve see Figure 7 is set in the factory at t...

Страница 15: ...are parts are not available the compressor station must be sent to the manufacturer for repair Figure 9 Change of Fine or Sterile Filter Note Membrane Dryer is shipped with a fine filter A sterile fil...

Страница 16: ...are exposed to pressure It must be ensured that the internal pressure will not permanently exceed the maxi mum working pressure PS stipulated on the vessel nameplate however it may momentarily do so...

Страница 17: ...and dimensions Specifications AirStar AERO100 100M AirStar AERO200 200M Dimensions H x W x D cm 68 x 64 x 49 68 x 64 x 49 Weight kgs 43 54 Delivery rate at Pe 0 bar 110 l min 0 bar 195 l min Delivery...

Страница 18: ...reater surface area Gasket defective Replace Cup seal leaking Remedy 1 Worn or pitted 1 Exchange cup seal cylinder and washers spare part kit 2 Very dirty 2 Change filter 3 Too high ambient temperatur...

Страница 19: ...7619 87620 9 Safety Relief Valve 87621 10 Tank Drain Valve 87622 11 Starting Sphere C1188 AERO100 and AERO200 ONLY 12 Non return valve receiver 87623 AERO100M and AERO200M ONLY 12 Non return valve rec...

Страница 20: ...Air Techniques Inc Page 20 Figure 10 AERO100 and AERO200 Parts Location AERO100 shown 1 3 4 2 5 13 7 12 11 14 9 8 8 10 6 4 Appendix 3 Spare Parts...

Страница 21: ...Note Membrane Dryer is shipped with a fine filter 17 A sterile filter 18 is an option Figure 11 AERO100M and AERO200M Parts Location AERO200M shown 3 2 13 8 16 15 5 6 5 6 9 12 3 2 10 4 14 7 Internal...

Страница 22: ...er and article number Order number as per parts list How many of each item required Exact address to dispatch to Dispatch details Repairs return delivery Please follow the packaging requirements liste...

Страница 23: ...Page 23 Air Techniques Inc Notes...

Страница 24: ...their practices to the next level Air Techniques family of quality products for the dental professional include Corporate Headquarters 1295 Walt Whitman Road Melville New York 11747 3062 Phone 800 24...

Отзывы: