it back in. if error repeats, call for service.
-
P2
: Water tank is full. Empty the water
tank.
-
ec
: Refrigerant leakage detection. With
this new technology, the display area
will appear
ec
when the unit detects
refrigerant leakage ,call for service
.
-
e3
: Unit malfunction. Unplug the unit and
plug it back in. if error repeats, call for
service.
-
eb
: Water tank is removed or not in right
position. Replace it bucket in the right
position.
⑩
Water tank full indicator light
The indicator lights to indicate that the tank
is full.
⑪
Auto defrost operation on indicator light
The indicator lights to indicate that auto
defrost operation is on.
HoW To uSe
•
Press "Power"
⑧
to turn on and off the
unit. The screen
⑨
illuminates when
Kompressor
is on.
•
The humidity level can be set with
⑦
pads and the digital display
⑨
.
•
Press the accurate pad in order to initiate
the desired function of
Kompressor
(see
"Control panel" and "Function" sections).
once the function is activated, the
concerned light indicator lights.
Press the button again to exit the selected
mode. When the tank is full or when it has not
been placed correctly, the LED "Full"
⑩
lights
and
Kompressor
stops.
FuNCTIoNS
How to use the different functions of
Kompressor
.
•
Auto Shut off
⑪
The unit shuts off when the bucket is full, or
when the bucket is removed or not replaced
in the proper position. When the setting
humidity is reached, the unit will be shut off
automatically.
•
Continuous mode
④
Continuous operation allows maximum
dehumidification. The unit dehumidifies
continuously, without taking into account the
relative humidity of the ambient air. CAUTioN:
on this mode, the
⑦
pads can not be
operated.
•
Mode HygroSmart
©
mode
HygroSmart
©
function allows maximum comfort
for the user. When this function is engaged,
the unit will automatically control the relative
humidity on a comfortable range between
45% ~ 55%, depending on the ambient
temperature.
CAUTioN: on this monde, the
⑦
pads can not be operated.
•
Turbo mode
⑤
Turbo operation allows to control the fan
speed for more efficiency. Set the fan control
to High for maximum moisture removal.
CAUTioN: When the humidity has been
reduced and quiet operation is preferred, set
the fan speed to normal
.
•
Timer
⑥
Kompressor
features an Auto Start and Auto
Stop function within a range of 0 to 24h
(increments of 0,5h between 0 and 10h ;
increments of 1h between 10 and 24h).
Case 1 : the unit is switched off
initialize Auto Start:
Press the timer button
⑥
(the "timer on"
indicator light illuminates) and use
⑦
pads to settle the Auto Start.
initialize Auto Stop:
Press the timer button
⑥
two times (the "timer
off" indicator light illuminates) and use
⑦
pads to settle the Auto Stop.
Case 2 : the unit is switched on
initialize Auto Stop:
Press the timer button
⑥
(the "timer off"
13
Downloaded from www.vandenborre.be