①
Pump pad
Press to activate the pump operation.
CAUTioN : Make sure the pump drain hose
is installed into the unit and the continuous
drain hose is removed from the unit before
the pump operation is activated.
②
HygroSmart
®
function pad
Press to activate the HygroSmart
®
dehumidifying operation. CAUTioN: on
this operation,the unit can not be set
humidity level.
③
Filter Pad
The check filter feature is a reminder
to clean the Air Filter for more efficient
operation. The Filter light(Clean filter light)
will illuminate after 250 hours of operation.
To reset after cleaning the filter, press the
Filter pad and the light will go off.
④
Continue mode pad
Press to activate the continuous
dehumidifying operation.
⑤
Turbo mode pad
Control the fan speed. Press to select
either High or Normal fan speed.
⑥
Timer pad
Press to initiate the Auto start and Auto
stop feature, in conjunction with the
⑦
key pads.
⑦
up/Down pads (
)
Humidity Set Control Pads:
For drier air, press the
pad and set to a
lower percent value (5% increments). For
damper air, press the pad and set a
higher percent value (5% increments).
Timer set control pads:
Use the
⑦
pads and set a higher
percent value.
⑧
Power pad
Press to turn the dehumidifier on and off.
⑨
LCD screen
The screen shows the actual room humidity
level then it shows the set humidity level
while setting the unit.
CAUTioN, the following error codes Can
be displayed :
-
AS
: humidity sensor error. Unplug the unit
and plug it back in. if error repeats, call
for service.
-
eS
: Tube Temperature sensor of the
evaporator error. Unplug the unit and plug
Kompressor
helps in preventing from moisture damage where books or valuables are stored, in
basements, etc. its built-in drain pump allows to drain condensates to a maximum height of
5 meters. in terms of hygiene and comfort, Air Naturel advices a relative humidity between
40 and 60%.
Starting the Kompressor
Before plugging the device on mains
power, check that the
Kompressor
is turned off.
if the unit was transported lying down, place
it in a vertical position and let it stand
3 hours
to let the refrigerant stabilizes.
When first using
the dehumidifier, operate the unit continuously
for 24 hours.
•
Place the humidifier on the floor.
•
Plug the power cord to the mains power
and turn the device on.
•
Check whether the filter is in place. Never
use the device without filter.
•
The
Dehumax
dehumidifier is now ready
to use
☺
.
CoNTroL PANeL
PUMP
HYGRO
SMART
©
FILTER CONTINUE TURBO
TIMER
POWER
Off
On
Full
Auto defrost
12