3 Installation of the Switch
•
The switch should not be placed near large electric motors or other strong electromagnetic
sources. As a reference, the strength of the electromagnetic field on site should not exceed the
(RFC) standards for IEC 801-3, Level 2(3V/M) field strength.
•
The air temperature in the location should be within a range of 32 to 122 °F (0 to 55°C).
•
The relative humidity in the location should not exceed 95% non-condensing humidity.
•
The distance between the RJ-45 port and the standard network interface should not exceed 100
meters.
•
Adequate space should be allowed in front of all the ports, so that each port is easily accessible
for cable connections.
Cabling Guide
For 100BASE-TX and 1000Base-T ports
The 24 10/100Mbps and 2 Gigabit station ports require Cat. 5 twisted-pair UTP/STP cable for
connection. When configuring within the 10/100BASE-TX cabling architecture, the cable distance
should be within 100m.
The following table summarizes the cable requirement for 10/100/1000BASE-T connection:
10BASE-T
100 ohm Category 3, 4, 5 UTP/STP cable
100BASE-TX
100 ohm Category 5 UTP/STP cable
1000Base-T
100 ohm Category 5 UTP/STP cable
Auto MDI/MDI-X function
The SNMP-FSH2402GT is equipped with Auto-MDI/MDI-X function, which allows you to use
straight-thru cable even when connecting to another switch/hub. Simply use the straight-through
cable for all types of 10/100/1000BASE-T connections, either to a PC or to a networking device
such as other hub or switch.
Connection
Specification
10 /100Base-TX
Ports
1000Base-T
Ports
Interface
RJ-45 RJ-45
Cable to Use
To an end station
Straight-through twisted-pair
cable
Straight-through twisted-pair
cable
To a hub/switch
Straight-through twisted-pair
cable
Straight-through twisted-pair
cable
Maximum Distance
100 meters
100 meters
Table 2-2 Cabling type for 10/100BASE-TX and 1000Base-T
11
Ether-FSH2402GT Gigabit Ethernet Switch User’s Manual V1.0