74
Starting-up and Operating the Wine Guardian Split System
Now that the installation is complete, check to make sure all ductwork and electrical connections
are secure.
Replace all panels that were removed during installation. Check that all the openings in the unit
are covered with a blank panel, a ductwork connection or a grille
.
CAUTION
RISK OF PERSONAL INJURY
COVER ALL OPENINGS OF THE UNIT TO PREVENT A HAND OR FINGER FROM ACCESS
INSIDE THE UNIT.
Turn on the Unit
Plug in the unit. Turn on the rocker switch on the side of the unit. The rocker switch lights up to
indicate power to the unit. The unit may not come on right away due to the timer built into the
circuiting to prevent short-cycling.
Testing the Fan
(Configuration Setting 7)
Factory default is “AUTO” fan operation. To change the fan setting, refer to page 52 of this
manual.
✓
ON means the fan runs continuously and indicates that the power is on
and the control circuit is energized and operating.
✓
AUTO means the fan runs only when the remote interface controller is
calling for cooling, heating, or the humidistat is calling for humidification.
Running the Unit
✓
Check unit to confirm the compressor is running, such as the hum of the
compressor or cool air leaving the unit.
✓
Check for any unusual noise or vibration, such as clanking or rubbing.
Initially, the unit may run continuously for several hours, up to a day or more, while it lowers the
cellar temperature. Once the unit reaches the setpoint temperature, it shuts off and starts to cycle
on and off as it continues to lower the bottle temperature to the setpoint. The cellar air reaches set
point before the bottles. If the cellar temperature started at 75°F (23° C) the supply air
temperature discharged from the unit will probably be 12 degrees to 15 degrees colder. As the
cellar temperature decreases to 55°F (13°C) the supply temperature differential decreases 8 to 12
degrees colder
.
NOTE: Temp flashes when cellar temperature falls below 65° F (18°C).
See page 56 for Hi Temp Alarm details.
Содержание 99H0360-10
Страница 12: ...12 Xtreme Low Ambient Illustrations Fig 1 Fig 2 Pressure cutout timer 33c0185 00...
Страница 14: ...14 Condensing unit dimensions DS050 COND NO OPTIONS...
Страница 15: ...15 Refrigeration Illustration of the system See next page for magnified image...
Страница 16: ...16 Magnified Image of the Condensing Unit...
Страница 17: ...17 Wiring Diagram for DS025 DS050 WGS40 WGS75...
Страница 18: ...18 Wiring Diagram for DS088 and WGS100...
Страница 19: ...19 Wiring Diagram for DS200 and WGS175 Units...
Страница 20: ...20 Wiring Diagram for Replacement Fan Motor XR 115 230 Models...
Страница 21: ...21 Wiring Diagram for DS025 and WGS40 Condensing Unit...
Страница 22: ...22 Wiring Diagram for DS050 and WGS75 Condensing Unit...
Страница 23: ...23 Wiring Diagram for DS088 and WGS100 Condensing Unit...
Страница 24: ...24 Wiring Diagram for DS200 and WGS175 Condensing Unit...
Страница 25: ...25 Ducted Split Systems Specifications 60Hz Models DS025 DS050 DS088 DS200...
Страница 26: ...26 Ducted Split System Specifications 50 Hz Models WGS40 WGS75 WGS100 WGS175...
Страница 44: ...44 Install refrigeration piping per local codes and ASHRAE guidelines...