39
General Duct Recommendations
✓
Support the flexible duct often to prevent sags or bends.
✓
Stretch the duct to make for a smoother interior for less air resistance.
✓
For a 90-degree bend, insert a metal elbow inside the flexible duct to avoid crimping.
✓
Do not squeeze or reduce the inside diameter of the ducts. This restricts the airflow.
✓
Use short and straight ductwork.
✓
Review the configuration schematic on the Overview sketch on page 13 for information
about which panels are available for duct connections and service.
✓
Remove the panels or grilles from the openings to connect the ductwork.
✓
Check that all the fan blades move freely.
✓
Check for loose foreign objects in any of the air paths.
✓
Connect the round flexible ducts to the Wine Guardian using the duct collars
provided with the duct accessory kit.
✓
Pull the outer plastic wrapping and insulation away from the end of the duct to
expose the reinforced inside duct liner.
✓
Use tie straps of clamp around the
inside liner
to fasten the duct collar
.
NOTE: Do not clamp around the outside insulation. It compresses and loosens
over time.
✓
Secure the duct collar to the unit using the screws provided. Be careful not to damage
or bend the gasket
.
Reducing Noise from the Unit
Consider noise when locating the unit close to the cellar or an adjacent occupied space. A piece of
one – or two-inch dense rubber or Styrofoam with foil face in between the unit and the wall
absorbs and reduces the noise from the unit. In case of air noise use larger grilles or block the
noise with a solid piece of wood or Styrofoam. Sound usually travels as a line of sight. Sound is
reduced when it turns a corner, such as passing through a bend in ductwork. If the unit is supported
from a wall or joist, place a rubber pad under the unit to reduce vibration transmission
.
Содержание 99H0360-10
Страница 12: ...12 Xtreme Low Ambient Illustrations Fig 1 Fig 2 Pressure cutout timer 33c0185 00...
Страница 14: ...14 Condensing unit dimensions DS050 COND NO OPTIONS...
Страница 15: ...15 Refrigeration Illustration of the system See next page for magnified image...
Страница 16: ...16 Magnified Image of the Condensing Unit...
Страница 17: ...17 Wiring Diagram for DS025 DS050 WGS40 WGS75...
Страница 18: ...18 Wiring Diagram for DS088 and WGS100...
Страница 19: ...19 Wiring Diagram for DS200 and WGS175 Units...
Страница 20: ...20 Wiring Diagram for Replacement Fan Motor XR 115 230 Models...
Страница 21: ...21 Wiring Diagram for DS025 and WGS40 Condensing Unit...
Страница 22: ...22 Wiring Diagram for DS050 and WGS75 Condensing Unit...
Страница 23: ...23 Wiring Diagram for DS088 and WGS100 Condensing Unit...
Страница 24: ...24 Wiring Diagram for DS200 and WGS175 Condensing Unit...
Страница 25: ...25 Ducted Split Systems Specifications 60Hz Models DS025 DS050 DS088 DS200...
Страница 26: ...26 Ducted Split System Specifications 50 Hz Models WGS40 WGS75 WGS100 WGS175...
Страница 44: ...44 Install refrigeration piping per local codes and ASHRAE guidelines...