IXW-MA Configuration

Station Numbers

Use the following steps for configuring the IXW-MA for use with the IXG Series. The IXW-MA has 10 configurable relay 
outputs than can be used for several functions, including remote door release and external signalling. IXG Support Tool 
v2.1.0.1 or later must be used. 

Note that the IXW-MA is not compatible with the IXG-DM7-HID Entrance Panel, only IX 

Series door stations.

The station number of any station interacting with the IXW-MA must be 3 to 5 digits long. For door release, this would be 
the station number of the door station, as it is what sends the SIF event to the IXW-MA relay.  To confirm or adjust station 

numbers, expand 

Station Information

 on the side menu and select 

Identification

SIF

In Advanced View

, found under 

View

 on the top menu, expand 

Function Settings

 on the side menu and select 

SIF

The example shown will be setting up remote door release, in which these settings will primarily be adjusted for the door 

stations, and not the master stations.

Enable

 

SIF Functionality

, enter 

0100 

for the Program Type

, set the IPv4 address to the IP address that will later be 

assigned to the IXW-MA, enter 

65014

 for the Destination Port, 

Enable

 SSL, and select 

Socket

 as the Connection. Click 

Save

  before continuing to Transmission Trigger.

Transmission Trigger

Scroll to the right and select the Transmission Trigger that will send the SIF event. Continuing with the previous example, 

Change Contact

 should be selected for remote door release activation.

Relay Output Time 

(Optional)

To increase the time the relay is closed on the IXW-MA when used for remote door release, expand 

Option Input/Relay 

Output

 and select Relay Output. Scroll to the right and adjust the 

Output Time 

for the door station accordingly. 

Once the previous steps are configured, each affected station will need to have the updated settings uploaded to it. For best 

practice, upload to all station to ensure consistent and up to date settings. To upload the settings to each station, select 

Connection

 on the top menu and click Upload Settings. 

Find more information on 

page 8

.

Upload Settings.

Содержание IXG Series

Страница 1: ...4 1 2 1 3 4 IXG SERIES IP Multi Tenant Video Intercom This is an abbreviated programming manual addressing basic program settings for an IXG System using the IXG Support Tool A complete set of instru...

Страница 2: ...uire advanced network configuration or routing to function properly in this environment It is possible for Windows Defender or other firewalls and antivirus software to block the broadcast the Support...

Страница 3: ...mmunicate with Inside and Outside Area units Guard and Entry Units as well as other Commercial Units The two private Door Stations will only call to stations within their Unit Commercial Unit x8 If up...

Страница 4: ...Management Company Information This information is a requirement for system or account recovery when using the IXG App Click Finish to continue Getting Started All ID and Passwords should be recorded...

Страница 5: ...the Units will have then click Apply Units Stations From left to right select the Building Number the Unit will belong to set the Unit Number and click the Unit Type button to select a Unit type This...

Страница 6: ...top of the screen to enter an IP address range to automatically assign all stations Edit the Admin ID and Password for each station as well as optionally create an ONVIF and RTSP ID and Password for...

Страница 7: ...correctly Typically stations deployed across a managed network cannot be found by Support Tool unless the network is configured to allow this broadcast search In this case it may be easier to move th...

Страница 8: ...enter an ID Password and Email Address Click Create to continue Once the Upload is complete select File from the top menu and click Export System Configuration Export this system s configuration to s...

Страница 9: ...QR Code is generated for each specific Residential Unit For Residential Units the app registration QR code can be sent directly to the IXG 2C7 Tenant Station in the Unit Select App Integration from th...

Страница 10: ...from the top menu and click Property Manager Settings Here tenants can be moved in and out Unit and Station names can be edited Mobile Apps can be added or removed from the system and other basic sys...

Страница 11: ...cess Codes to allow residents or known visitors to enter the building by entering a code at the Entrance Station Up to 9 999 codes can be created At the top of the screen use the drop down options to...

Страница 12: ...an record audio and video to a local microSD card when a call is placed or once communication is established with a station Enable these functions by expanding Function Settings and clicking Recording...

Страница 13: ...usted for the door stations and not the master stations Enable SIF Functionality enter 0100 for the Program Type set the IPv4 address to the IP address that will later be assigned to the IXW MA enter...

Страница 14: ...ect Relay Output Starting with Relay Output 1 select Contact Change SIF Event and then specify the Station Number of the station activating the Relay Output 1 Once these values are set click Update De...

Отзывы: