Aiphone IXG Series Скачать руководство пользователя страница 3

If updating dimensions, be sure to update the GLC layer too.

Please refer to the Product Dimensions Master located here:

H:\Engineering Services\Product Dimensions Master Document\Product Dimensions Master.xlsx

IXG-DM7

7-3/16"

1-1/2"

1/2"

13

-1

1/

16

"

If updating dimensions, be sure to update the GLC layer too.

Please refer to the Product Dimensions Master located here:

H:\Engineering Services\Product Dimensions Master Document\Product Dimensions Master.xlsx

IX-DV

IX-DV

8-1

/8

"

4-1/2"

1-3/4"

If updating dimensions, be sure to update the GLC layer too.

Please refer to the Product Dimensions Master located here:

H:\Engineering Services\Product Dimensions Master Document\Product Dimensions Master.xlsx

IXG-2C7

8-15/16"

1"

5-1

3/

16

"

Residential Units may consist of up to eight IXG-2C7 tenant stations or 

IX-RS-* Handset Sub Stations, eight IXG Apps, or a combination of both. Tenant 

Stations can communicate internally within the Unit, receive incoming calls from 

Entrance and Guard Units, and monitor Entrance Stations. The two private door 

stations will only call to stations within their Unit.

Residential Unit

x8

Entrance Units consist of IXG-DM7-* Entrance Stations. Entrance Stations can call Guard, 

Commercial, and Tenant Units and their stations, as well as grant entry to residents by keypad 

or card reader.

x10

Entrance Unit

x2

x8

If updating dimensions, be sure to update the GLC layer too.

Please refer to the Product Dimensions Master located here:

H:\Engineering Services\Product Dimensions Master Document\Product Dimensions Master.xlsx

IX-DV

IX-DV

8-1

/8

"

4-1/2"

1-3/4"

x2

Commercial Units consist of up to eight IX-MV7-* Master Stations or IX-RS-* 

Handset Sub Stations, eight IXG Apps, or a combination of both. These master 

stations can utilize many IX Series functions including internal paging, call 

transfer, speed dial buttons, and more. 

Stations within a Commercial Unit can communicate with Inside and Outside 

Area units, Guard and Entry Units, as well as other Commercial Units. The two 

private Door Stations will only call to stations within their Unit.

Commercial Unit

x8

If updating dimensions, be sure to update the GLC layer too.

Please refer to the Product Dimensions Master located here:

H:\Engineering Services\Product Dimensions Master Document\Product Dimensions Master.xlsx

IX-DV

IX-DV

8-1

/8

"

4-1/2"

1-3/4"

If updating dimensions, be sure to update the GLC layer too.

Please refer to the Product Dimensions Master located here:

H:\Engineering Services\Product Dimensions Master Document\Product Dimensions Master.xlsx

IX-DV

IX-DV

8-1

/8

"

4-1/2"

1-3/4"

x2

Guard Units consist of up to eight IXG-MK Guard Stations or IX-RS-* Handset 

Sub Stations, up to eight IXG Apps, or a combination of both. The two private 

Door Stations will only call to stations within their Unit.

Guard Unit

x8

Inside Area Units consist of up to eight IX-MV7-* Master Stations or IX-RS-* 

Handset Sub Stations, and two IX Series Door Stations. These stations can 

utilize many IX Series functions including internal paging, call transfer, speed 

dial buttons, and more. 

An Inside Area Master Station can communicate with all other Unit types, 

except for the Guard Unit. The two private Door Stations will only call to 

stations within their Unit.

Inside Area Unit

If updating dimensions, be sure to update the GLC layer too.

Please refer to the Product Dimensions Master located here:

H:\Engineering Services\Product Dimensions Master Document\Product Dimensions Master.xlsx

IX-DV

IX-DV

8-1

/8

"

4-1/2"

1-3/4"

Outside Area Units consist of up to 10 Door or Emergency Stations that can call 

Residential, Guard, Commercial, and Inside Area units. 

Outside Area Unit

Unit Types

x2

x10

The IXG Series has six different Unit types: 

Entrance

Guard

Residential

Commercial

Inside Area

and 

Outside Area

. Each has their own purpose, available features, communication paths, and station types. 

There are no limitations to the number of Units a system can have, but each Unit type has station quantity 

limitations. 

Содержание IXG Series

Страница 1: ...4 1 2 1 3 4 IXG SERIES IP Multi Tenant Video Intercom This is an abbreviated programming manual addressing basic program settings for an IXG System using the IXG Support Tool A complete set of instru...

Страница 2: ...uire advanced network configuration or routing to function properly in this environment It is possible for Windows Defender or other firewalls and antivirus software to block the broadcast the Support...

Страница 3: ...mmunicate with Inside and Outside Area units Guard and Entry Units as well as other Commercial Units The two private Door Stations will only call to stations within their Unit Commercial Unit x8 If up...

Страница 4: ...Management Company Information This information is a requirement for system or account recovery when using the IXG App Click Finish to continue Getting Started All ID and Passwords should be recorded...

Страница 5: ...the Units will have then click Apply Units Stations From left to right select the Building Number the Unit will belong to set the Unit Number and click the Unit Type button to select a Unit type This...

Страница 6: ...top of the screen to enter an IP address range to automatically assign all stations Edit the Admin ID and Password for each station as well as optionally create an ONVIF and RTSP ID and Password for...

Страница 7: ...correctly Typically stations deployed across a managed network cannot be found by Support Tool unless the network is configured to allow this broadcast search In this case it may be easier to move th...

Страница 8: ...enter an ID Password and Email Address Click Create to continue Once the Upload is complete select File from the top menu and click Export System Configuration Export this system s configuration to s...

Страница 9: ...QR Code is generated for each specific Residential Unit For Residential Units the app registration QR code can be sent directly to the IXG 2C7 Tenant Station in the Unit Select App Integration from th...

Страница 10: ...from the top menu and click Property Manager Settings Here tenants can be moved in and out Unit and Station names can be edited Mobile Apps can be added or removed from the system and other basic sys...

Страница 11: ...cess Codes to allow residents or known visitors to enter the building by entering a code at the Entrance Station Up to 9 999 codes can be created At the top of the screen use the drop down options to...

Страница 12: ...an record audio and video to a local microSD card when a call is placed or once communication is established with a station Enable these functions by expanding Function Settings and clicking Recording...

Страница 13: ...usted for the door stations and not the master stations Enable SIF Functionality enter 0100 for the Program Type set the IPv4 address to the IP address that will later be assigned to the IXW MA enter...

Страница 14: ...ect Relay Output Starting with Relay Output 1 select Contact Change SIF Event and then specify the Station Number of the station activating the Relay Output 1 Once these values are set click Update De...

Отзывы: