INSTRUCTIONS FOR USE
AGS 400-1200 EN
Rev.12/2018
44
9.5.2
CONTROL PANEL
Figure 35: Control panel
1-
MAIN valve control
2-
Switch for precise operating pressure adjustment
The MAIN valve and the control valve (pressure regulation) are both controlled exclusively with the
switches 1 and 2 on the control panel.
The control panel uses 12V power supply by means of a cable supplied with the panel to connect to the
electrical system of the tractor.
9.5.3
PRESSURE GAUGE
Figure 36: Pressure gauge
Diameter of the standard pressure gauge (class 1.6) installed on the pressure regulator is 63 mm. This
is a two-range pressure gauge. The first range of 0-8 bar is coloured green and the second range of 8-
20 bar is coloured yellow or red. The pressure gauge is filled with glycerine to ensure that the indicator
remains steady. During winter, it is recommended to remove the pressure gauge and store it
somewhere warm if the sprayer is exposed to temperatures below the freezing point of water.
The pressure regulator can also be equipped with a larger pressure gauge with a diameter of 100 mm
(optional equipment).